Related Experiment Video
Updated: Oct 17, 2025

A Preclinical Model of Exertional Heat Stroke in Mice
Published on: July 1, 2021
The impact of elevated body core temperature on critical power as determined by a 3-min all-out test
Brendan W Kaiser1, Ka'eo K Kruse2, Brandon M Gibson1
1Department of Human Physiology, University of Oregon, Eugene, Oregon.
Abstract:
Critical power (CP) delineates the heavy and severe exercise intensity domains, and sustained work rates above CP result in an inexorable progression of oxygen uptake to a maximal value and, subsequently, the limit of exercise tolerance. The finite work capacity above CP, W', is defined by the curvature constant of the power-duration relationship. Heavy or severe exercise in a hot environment generates additional challenges related to the rise in body core temperature (Tc) that may impact CP and W'. The purpose of this study was to determine the effect of elevated Tc on CP and W'. CP and W' were estimated by end-test power (EP; mean of final 30 s) and work above end-test power (WEP), respectively, from 3-min "all-out" tests performed on a cycle ergometer. Volunteers (n = 8, 4 female) performed the 3-min tests during a familiarization visit and two experimental visits (thermoneutral vs. hot, randomized crossover design). Before experimental 3-min tests, the subjects were immersed in water (thermoneutral: 36°C for 30 min; hot: 40.5°C until Tc was ≥38.5°C). Mean Tc was significantly greater in the hot condition than in the thermoneutral condition (38.5 ± 0.0°C vs. 37.4 ± 0.2°C; means ± SD, P < 0.01). All 3-min tests were performed in an environmental chamber [thermoneutral: 18°C, 45% relative humidity (RH); hot: 38 °C, 40% RH]. EP was similar between thermoneutral (239 ± 57 W) and hot (234 ± 66 W; P = 0.55) conditions. WEP was similar between thermoneutral (10.9 ± 3.0 kJ) and hot conditions (9.3 ± 3.6; P = 0.19). These results suggest that elevated Tc has no significant impact on EP or WEP.NEW & NOTEWORTHY The parameters of the power-duration relationship (critical power and W') estimated by a 3-min all-out test were not altered by elevated body core temperature as compared with a thermoneutral condition.
More Related Videos
Related Concept Videos
Factors Affecting Body Temperature
Factors may include:
Increased Body Temperature
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Homeostatic Imbalances in Body Temperature
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...

