Real-Time Multi-Ion-Monitoring Front-End With Interference Compensation by Multi-Output Support Vector Regressor
Abstract:
Ion-sensors play a major role in physiology and healthcare monitoring since they are capable of continuously collecting biological data from body fluids. Nevertheless, ion interference from background electrolytes present in the sample is a paramount challenge for a precise multi-ion-monitoring. In this work, we propose the first system combining a battery-powered portable multi-channel electronic front-end, and an embedded Multi-output Support Vector Regressor (M-SVR), that supplies an accurate, continuous, and real-time monitoring of sodium, potassium, ammonium, and calcium ions. These are typical analytes tracked during physical exercise. The front-end interface was characterized through a sensor array built with screen-printed electrodes. Nernstian sensitivity and limit of detection comparable to a bulky laboratory potentiometer were achieved in both water and artificial sweat. The multivariate calibration model was deployed on a Raspberry Pi where the activity of the target ions were locally computed. The M-SVR model was trained, optimized, and tested on an experimental dataset acquired following a design of experiments. We demonstrate that the proposed multivariate regressor is a compact, low-complexity, accurate, and unbiased estimator of sodium and potassium ions activity. A global normalized root mean-squared error improvement of 6.97%, and global mean relative error improvement of 10.26%, were achieved with respect to a standard Multiple Linear Regressor (MLR). Within a real-time multi-ion-monitoring task, the overall system enabled the continuous monitoring and accurate determination of the four target ions activity, with an average accuracy improvement of 27.73% compared to a simple MLR, and a prediction latency of [Formula: see text].
More Related Videos
11:54Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
Published on: March 13, 2017
11:25Simultaneous Scalp Electroencephalography EEG, Electromyography EMG, and Whole-body Segmental Inertial Recording for Multi-modal Neural Decoding
Published on: July 26, 2013
Related Concept Videos
Multi-input and Multi-variable systems
In the absence...
Power Factor Correction
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Multiple Voltage Sources
In series, the positive terminal of one battery is connected to the negative terminal of another battery. Hence, the voltage of each battery is added to give the net voltage, which is increased because each battery boosts the electrons that enter it. The same current flows through each battery because they are connected in series.
Batteries are...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Classification of Signals
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...