Related Experiment Video
Updated: Oct 17, 2025

Systematic Approach to Identify Novel Antimicrobial and Antibiofilm Molecules from Plants' Extracts and Fractions to Prevent Dental Caries
Published on: March 31, 2021
Chemometrics analysis for the detection of dental caries via UV absorption spectroscopy
Katrul Nadia Basri1, Farinawati Yazid2, Rohaya Megat Abdul Wahab2
1School of Electrical Engineering, College of Engineering, Universiti Teknologi MARA, 40450 Shah Alam, Selangor, Malaysia.
Abstract:
Caries is one of the non-communicable diseases that has a high prevalence trend. The current methods used to detect caries require sophisticated laboratory equipment, professional inspection, and expensive equipment such as X-ray imaging device. A non-invasive and economical method is required to substitute the conventional methods for the detection of caries. UV absorption spectroscopy coupled with chemometrics analysis has emerged as a good potential candidate for such an application. Data preprocessing methods such as mean centre, autoscale and Savitzky-Golay smoothing were implemented to enhance the signal-to-noise ratio of spectra data. Various classification algorithms namely K-nearest neighbours (KNN), logistic regression (LR) and linear discriminant analysis (LDA) were implemented to classify the severity of dental caries into International Caries Detection and Assessment System (ICDAS) scores. The performance of the prediction model was measured and comparatively analysed based on the accuracy, precision, sensitivity, and specificity. The LDA algorithm combined with the Savitzky-Golay preprocessing method had shown the best result with respect to the validation data accuracy, precision, sensitivity and specificity, where each had values of 0.90, 1.00, 0.86 and 1.00 respectively. The area under the curve of the ROC plot computed for the LDA algorithm was 0.95, which indicated that the prediction algorithm was capable of differentiating normal and caries teeth excellently.
Related Concept Videos
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
UV–Vis Spectrometers
UV–Vis Spectroscopy: Woodward–Fieser Rules
UV–Vis Spectrum
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent...

