Related Experiment Video
Updated: Oct 17, 2025

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Alternating in-source fragmentation with single-stage high-resolution mass spectrometry with high annotation
Hendri Wasito1, Tim Causon2, Stephan Hann2
1Institute of Analytical Chemistry, Department of Chemistry, University of Natural Resources and Life Sciences, Vienna (BOKU), Muthgasse 18, 1190, Vienna, Austria; Department of Pharmacy, Faculty of Health Sciences, Jenderal Soedirman University, Dr. Soeparno Street, 53122, Purwokerto, Indonesia.
Abstract:
Non-targeted metabolomics is increasingly applied in various applications for understanding biological processes and finding novel biomarkers in living organisms. However, high-confidence identity confirmation of metabolites in complex biological samples is still a significant bottleneck, especially when using single-stage mass analysers. In the current study, a complete workflow for alternating in-source fragmentation on a time-of-flight mass spectrometry (TOFMS) instrument for non-targeted metabolomics is presented. Hydrophilic interaction liquid chromatography (HILIC) was employed to assess polar metabolites in yeast following ESI parameter optimization using experimental design principles, which revealed the key influence of fragmentor voltage for this application. Datasets from alternating in-source fragmentation high resolution mass spectrometry (HRMS) were evaluated using open-source data processing tools combined with public reference mass spectral databases. The significant influence of the selected fragmentor voltages on the abundance of the primary analyte ion of interest and the extent of in-source fragmentation allowed an optimum selection of qualifier fragments for the different metabolites. The new acquisition and evaluation workflow was implemented for the non-targeted analysis of yeast extract samples whereby more than 130 metabolites were putatively annotated with more than 40% considered to be of high confidence. The presented workflow contains a fully elaborated acquisition and evaluation methodology using alternating in-source fragmentor voltages suitable for peak annotation and metabolite identity confirmation for non-targeted metabolomics applications performed on a single-stage HRMS platform.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Molecular Fragmentation Overview
One type of fragmentation pattern is the cleavage of a single bond in the molecular ion. The cleavage leads to a radical and a cation. The cleavage can...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Resolution Mass Spectrometry (HRMS)
Mass Spectrometry: Overview
Mass Analyzers: Overview