Related Experiment Video
Updated: Oct 17, 2025

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Early Failure of a Bioprosthetic Valve in the Pulmonary Position Causing Panic
Alexander K Reed1, Julian A Villaba2, Duke E Cameron3
1Harvard Medical School, Boston, Massachusetts.
Abstract:
An asymptomatic 26-year-old woman with repaired tetralogy of Fallot and a bioprosthetic pulmonary valve presented with a large thrombosis occluding most of her right ventricular outflow tract and main pulmonary arteries. Our pulmonary embolism response team was emergently consulted, resulting in considerable discussion regarding the treatment modality given the large size and high-risk nature of the thrombosis. Ultimately, she was started on a heparin infusion until she could undergo open thrombectomy and pulmonary valve repeat replacement. The patient's asymptomatic presentation, despite the considerable clot burden, complicated our approach to management but ultimately led to a measured and timely intervention.