Introduction:
Unplanned extubations (UEs) refer to the inadvertent removal of endotracheal tubes (ETTs). Superficially placed ETTs anecdotally increases the risk of UEs. This study aims to assess the impact of ETT position as well as other factors that could be associated with risk of UEs.
Method:
A retrospective case-control study was conducted at NewYork-Presbyterian Queens Hospital from January 2017 to February 2020. All adults admitted to intensive care units (ICUs) who received mechanical ventilation (MV) through ETTs were screened to identify UEs. For each case with UE, two controls with planned extubation were identified. A multivariate logistic regression was conducted to identify risk factors associated with UEs.
Results:
1100 patients received MV through ETTs during the time period. The incidence of UE was 4.9%. 53 patients with UEs and 106 patients with planned extubation were included for statistical analysis. Overall, patients with UE had higher in-hospital mortality rates (26.4% versus 11.3%, P = 0.02) and reintubation rates (28.3% versus 6.6%, P < 0.001). Within the UE group, patients who required reintubation had significantly higher in-hospital mortality rates than those who did not require reintubation (53.3% versus 15.8%, P = 0.005). Multivariate logistic regression showed higher APACHE II scores (Odds ratios (OR) 1.07; 95% Confidence interval (CI), 1 to 1.13), distance of ETT tips to carina ≥6 cm (OR 6.41; 95% CI, 1.1 to 37.3), physical restraint use (OR 2.98; 95% CI, 1.28 to 6.95) and continuous infusions of sedatives and/or analgesics (OR 10.72, 95% CI, 4.19 to 27.43) were associated with UE.
Conclusion:
UE and the need for reintubation is associated with worse outcomes. Distance of ETT tips to carina ≥6 cm may be associated with higher risks of UE. Further prospective studies are needed to establish the optimal position of ETT to prevent UE.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...