Transthoracic echo-guided pacemaker implantation reduces fluoroscopic use in dogs
F Porciello1, M C Marchesi1, F Birettoni1
1Department of Veterinary Medicine, University of Perugia, Via San Costanzo 4, Perugia, 06126 Italy.
Abstract:
Echocardiographic guidance provides an alternative method when fluoroscopy is unavailable, equipment or power failure of fluoroscopic equipment during a procedure occurs or to decrease radiation risk. Recently, transthoracic (TTE) and transesophageal echocardiography were reported as an alternative method to guide interventional procedures in dogs. Therefore, we hypothesized that TTE could be used as an alternative method to visualize endocardial leads during pacemaker implantation in dogs, largely avoiding the use of fluoroscopy. A prospective consecutive case series of pacemaker implantation was performed using TTE guidance. The endocardial lead was imaged by TTE during its intracardiac advancement until the lead tip was positioned at the right ventricular apex. Echocardiographic right parasternal views, optimized to visualize the pacing lead, were used, starting with a short axis image of the right atrium and ending with a long axis view of the right ventricle (RV) optimized to image the RV apex. Proper lead placement was confirmed by both capture threshold, impedance and fluoroscopy. Twenty-one pacemaker implantation procedures by TTE monitoring were successfully performed. The TTE guidance provided images of a quality sufficient to clearly monitor implantation in real-time and allowed for immediate corrections to pacing lead malpositioning or excessive looping. Fluoroscopy was used to confirm the correct placement of the lead that was guided echocardiographically in the initial three procedures, after which a single radiographic image (no cine-mode) was used to identify lead placement and redundancy in the remaining eighteen cases. Static imaging (radiography using the fluoroscope) was used to assess the proper lead redundancy in all procedures because this cannot be evaluated echocardiographically. Pacemaker leads were successfully implanted in the RV of dogs using TTE monitoring. A larger cases series is needed for validation of safety and effectiveness of TTE during this interventional procedure in dogs.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012