Related Experiment Video
Updated: Oct 16, 2025

Modified Octopus Technique for Thoracoabdominal Aortic Aneurysm
Published on: August 1, 2025
Obstructive Jaundice Caused by a Large Intact Abdominal Aortic Aneurysm. Case Report and Literature Review
Manolis Abatzis-Papadopoulos1, Dimitrios Karamanos1, Ioakeim Papoutsis1
1Vascular Unit, 1st University Surgical Department, Papageorgiou General Hospital, Aristotle University, Thessaloniki, Greece.
Background:
Obstructive jaundice caused by abdominal aortic aneurysm (AAA) is an extremely rare clinical presentation. We present an 85-year-old male with a large intact AAA causing obstructive jaundice and review the relevant literature.
Methods And Results:
The patient was referred to our hospital with jaundice and a palpable pulsatile abdominal mass. Computerized tomography (CT) angiogram and magnetic resonance cholangiopancreatography (MRCP) revealed an infrarenal AAA with maximal diameter of 8.5 cm compressing the pancreatic head and common bile duct, causing obstructive jaundice with elevated levels of total, and direct bilirubin. The patient was subjected to endovascular aneurysm repair (EVAR). Blood bilirubin gradually decreased to normal levels. No complications were reported during the immediate postoperative and at 3-month follow up period. Literature review suggests that our case is one of the largest intact AAAs which have been reported to cause biliary obstruction.
Conclusions:
AAAs causing secondary obstructive jaundice is an uncommon clinical presentation requiring high clinical suspicion during differential diagnosis, so that patients can receive proper and early diagnosis and treatment.