Continuous Noninvasive Blood Pressure Monitoring of Beat-By-Beat Blood Pressure and Heart Rate Using Caretaker
Younghoon Kwon1, Patrick L Stafford2, Kyle Enfield2
1Department of Medicine, University of Washington, Seattle, WA.
Objective:
To examine the accuracy of noninvasively-derived peripheral arterial blood pressure (BP) by the Caretaker device (CT) against invasively measured arterial BP and the fidelity of heart rate variability by CT compared with electrocardiogram (ECG)-derived data.
Design:
Prospective cohort study.
Participants:
Adult surgical and trauma patients admitted to the intensive care unit.
Setting:
Academic tertiary care medical center.
Interventions:
In a prospective manner, beat-by-beat BP by CT was recorded simultaneously with invasive arterial BP measured in patients in the intensive care unit. Invasive arterial BPs were compared with those obtained by the CT system. All comparisons among the CT data, arterial catheter data, and ECG data were postprocessed.
Measurements And Main Results:
From 37 enrolled patients, 34 were included with satisfactory data that overlapped between arterial catheter and CT. A total of 87,757 comparative data points were obtained for the 40-minute time window comparisons of the 34 patients, spanning approximately 22.5 hours in total. Systolic BP and diastolic BP correlations (Pearson coefficient), as well as the mean difference (standard deviation), were 0.92 and -0.36 (7.57) mmHg and 0.83 and -2.11 (6.00) mmHg, respectively. The overall interbeat correlation was 0.99, with the mean difference between interbeats obtained with the arterial BP and the CT of -0.056 ms (6.0).
Conclusions:
This study validated the noninvasive tracking of BP using the CT device, and the pulse decomposition analysis approach is possible within the guidelines of the standard.
More Related Videos
07:35Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
09:38Femoral Arterial and Venous Catheterization for Blood Sampling, Drug Administration and Conscious Blood Pressure and Heart Rate Measurements
Published on: January 24, 2012
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Holter Monitor: 24-Hour Monitoring
Pre-Procedural Guidelines for Assessing Blood Pressure