Related Experiment Video
Updated: Oct 16, 2025

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
A Comparative Study between Truview PCD Video Laryngoscope and Macintosh Laryngoscope with Respect to Intubation
Rajiba Lochan Samal1, Sumita Swain1, Soumya Samal1
1Department of Anaesthesiology, IMS and SUM Hospital, SOA Deemed to be University, Bhubaneswar, Odisha, India.
Background And Aims:
Video laryngoscopes resemble traditional laryngoscopes, but they have a video chip embedded in the tip of laryngoscope blade. This enables the operator to "look around the corners" which is not possible with conventional direct laryngoscopes. The present study was undertaken to compare Truview video laryngoscope and Macintosh laryngoscope for glottis visualization, ease of tracheal intubation, and associated hemodynamic response.
Setting:
The study was conducted in operation theater in a medical college.
Study Design:
It was a randomized prospective observational study.
Materials And Methods:
Sixty patients of American Society of Anesthesiologists Grade 1 and 2 of either sex aged 18-60 years who were scheduled to undergo elective surgery requiring general anesthesia with orotracheal intubation were selected. In patients of Group T (n = 30), intubation was done using Truview video laryngoscope, while in Group M (n = 30), intubation was done using Macintosh laryngoscope. Various airway and hemodynamic parameters were assessed and compared.
Statistical Analysis:
Statistical analysis was done using Chi-square test, paired and unpaired Student's t-test, and ANOVA test. P < 0.05 is considered statistically significant.
Results:
Distribution of modified Mallampati Class (MMPC), ease of laryngoscopic blade insertion, and size of cuffed endotracheal tube used were statistically comparable in both the groups. The time to intubation was more in Group T (37.16 ± 8.23 s) as compared to Group M (29.80 ± 6.75 s). There was a statistically significant better modified Cormack and Lehane (CL) grading view obtained in Group T as compared to Group M (P = 0.025). CL Grades 2 and 3 were not seen in any of either of the group. The mean intubation difficulty score (IDS) was significantly lower in Group T (0.3 ± 0.60) as compared to Group M (0.73 ± 0.86). In both the Groups T and M, the mean heart rate, systolic blood pressure (BP), and diastolic BP were significantly increased from baseline for up to 3 min after laryngoscopy, but they were comparable between the two groups all the time.
Conclusion:
Truview propaganda cum distribution laryngoscope provides a better glottis view than the Macintosh laryngoscope. Although it requires a longer time to intubate using Truview, the overall IDS score was lower as compared to Macintosh laryngoscope. Hemodynamic changes remained similar in both the groups.
More Related Videos
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Suctioning II: Procedure
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...

