Abstract:
Coumarin is a phytotoxin found in the popular spice cinnamon, which is used to flavor many Asian curry dishes. In this work, we developed and compared the analytical performance of reversed-phase liquid chromatography (RP-LC) and sweeping-micellar electrokinetic chromatography (MEKC) methods for the determination of coumarin in complex curry (gravy) samples. Using a matrix matched sample (curry after solvent extraction with methanol and diluted with 100 mM phosphoric acid), the intra-day and inter-day repeatability of retention/migration time and (corrected) peak area for both methods were acceptable (%RSD (n=6) ≤ 5%). The linear range and limit of quantitation (LOQ) were an order of magnitude better in RP-LC (RP-LC linear range = 0.11-108 mg/kg, LOQ = 0.11 mg/kg) (Sweeping-MEKC linear range = 2.16-216 mg/kg, LOQ = 2.16 mg/kg). However, the limit of detection (S/N=3) and LOQ in sweeping-MEKC was 0.65 mg/kg and 2.16 mg/kg, which were sufficient to report the levels of coumarin ≥ the European limit of 2 mg/kg in foods. During the analysis of 25 curry samples, relatively similar results for sweeping-MEKC and RP-LC were obtained for 6 samples that contained coumarin >LOQ of sweeping-MEKC. Interferences in RP-LC lead to significant overestimation of coumarin levels in 3 samples. Coumarin levels above the EU limit was found in 6 curry samples using the more selective sweeping-MEKC. This work should also raise public awareness on the presence of potentially high levels of coumarin in some foods.
More Related Videos
09:56Real-time Monitoring of Reactions Performed Using Continuous-flow Processing: The Preparation of 3-Acetylcoumarin as an Example
Published on: November 18, 2015
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
High-Performance Liquid Chromatography: Elution Process
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Principles Of Column Chromatography