Making computed tomography safer for patients with Crohn's disease
John O'Grady1,2, Brian W Carey3, Richard G Kavanagh3
1APC Microbiome Ireland, University College Cork, National University of Ireland, Cork, Ireland.
Low-dose computed tomography (CT) significantly reduces radiation exposure by 76.5% in Crohn's disease patients. This safe and accurate imaging method effectively evaluates disease complications, making it a viable standard of care.
Area of Science:
- Radiology
- Gastroenterology
- Medical Imaging
Background:
- Computed tomography (CT) is widely used for Crohn's disease but involves radiation exposure.
- Modern CT technology allows for significant radiation dose reduction without compromising accuracy.
- Magnetic resonance imaging (MRI) is an alternative but less accessible than CT.
Purpose of the Study:
- To compare the clinical confidence and accuracy of low-dose CT versus conventional-dose CT in patients with known Crohn's disease.
- To assess the effectiveness of low-dose CT in the semi-acute setting for evaluating Crohn's disease complications.
- To determine the radiation dose reduction achieved with low-dose CT.
Main Methods:
- A comparative study involving 50 consecutive outpatients with Crohn's disease.
- Evaluation of low-dose CT with full iterative reconstruction (IR) against conventional-dose CT.
- Clinicians reviewed low-dose images and reports, with conventional-dose images reviewed after a 4-week interval.
Main Results:
- Low-dose IR imaging adequately addressed the clinical question in all cases.
- Crohn's disease complications were detected in 74% of patients with no disagreement between low- and conventional-dose imaging.
- An effective radiation dose reduction of 76.5% was achieved (2.15 mSv vs. 6.99 mSv).
Conclusions:
- Low-dose IR CT is a safe and accurate method for evaluating Crohn's disease distribution and complications in outpatients.
- Low-dose radiation imaging should be considered the standard of care for Crohn's disease evaluation.
- Low-dose CT is an acceptable alternative to MRI, especially in acute settings.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
06:49Orthotopic Implantation of Patient-Derived Cancer Cells in Mice Recapitulates Advanced Colorectal Cancer
Published on: February 10, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Drugs for Treatment of Crohn's Disease in IBD Using Biologic Agents: Anti-TNF