Experimental Methods for Trapping Ions Using Microfabricated Surface Ion Traps
Published on: August 17, 2017
Ion scanning or ion trapping: Why not both?
Andrea Raffaelli1, Alessandro Saba2,3
1Institute of Life Sciences-S. Anna School of Advanced Studies, Pisa, Italy.
Abstract:
The present contribution describes analogies and differences between the quadrupolar ion trap (QIT) and the quadrupole mass analyzers, shows the potentialities of their combination in a single instrument and presents a review of applications of such a technology in different fields. The first section describes the quadrupole mass filter (QMF), outlining its principles of operation and the ion sorting procedure according to the use of oscillating electric fields inducing stable trajectories to the ions allowing them to reach the detector. Multiple quadrupole systems (normally triple quadrupoles) are then explained, showing their use in tandem mass spectrometry in space experiments (MS/MS-in-space). QIT principles of operation are then examined, pointing out that in this case the use of the same combination of oscillating electric fields takes advantage of unstable ion trajectories for their sorting. Substantially, analogies and differences between QMF and QIT come out, which consist in the fact that QMF is a scanning mass analyzer, whereas QIT is a sequential mass analyzer. In addition, the section underlines that QIT is capable to perform tandem mass spectrometry in time experiments (MS/MS-in-time). Later, the possibility to use a quadrupole as a trapping system with a prevailing dimension (linear ion trap [LIT]) is taken into consideration, and the possibility to combine both QMF and LIT in a single instrument, a QTrap mass spectrometer, is illustrated. In this frame, a lot more experiment types are possible with respect to both standalone triple quadrupoles and LIT, and they are described as well. Several combinations of these QTrap features can be used in information dependent acquisition (IDA) mode, allowing the high versatility of this instrumental configuration. The second section deals with a review of applications in different fields. These are organized by kind of QTrap and IDA features and cover different topics in biological, medical, agrochemical, nutritional and environmental fields.
Related Concept Videos
Mass Analyzers: Common Types
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Chemical Ionization (CI) Mass Spectrometry