Related Experiment Video
Updated: Oct 14, 2025

Estimation of Urinary Nanocrystals in Humans using Calcium Fluorophore Labeling and Nanoparticle Tracking Analysis
Published on: February 9, 2021
Quantitative assessment of crystal dissolution in gout during urate-lowering therapy with computer-aided MicroPure
Qiao Wang1,2,3,4, Hui Bao5, Le-Hang Guo1,2,3,4
1Department of Medical Ultrasound, Shanghai Skin Disease Hospital, School of Medicine, Tongji University, Shanghai, China.
Background:
To evaluate whether MicroPure imaging, an ultrasound (US) image-processing technique with computer-aided analysis, can quantitatively detect crystal dissolution during urate-lowering therapy (ULT) in gout.
Methods:
This was a prospective study of gout patients requiring ULT. The first metatarsophalangeal joints were examined using US and MicroPure before and after 3 months of ULT. Elementary lesions of gout, including the double contour sign (DCS), aggregates, tophi, erosion, and other US features were recorded at baseline and 3 months. MicroPure imaging features were automatically calculated by a self-developed software. Patients were divided into goal-achieved and goal-not-achieved groups according to their urate levels at 3 months. The US and MicroPure imaging features of the two groups were analyzed at baseline and 3 months.
Results:
A total of 55 consecutive patients were enrolled (25: goal-achieved group; 30: goal-not-achieved group). US findings demonstrated that the power Doppler signal grade decreased at 3 months, regardless of the group (both P<0.05). From baseline to 3 months, tophi size and the DCS reduced in the goal-achieved group (both P<0.05), while the US aggregate features showed no difference (P=0.250). However, on the MicroPure imaging, the number and density of aggregates at 3 months decreased in the goal-achieved group (both P<0.05). There were no significant changes at 3 months in any of the MicroPure imaging features in the goal-not-achieved group (all P>0.05).
Conclusions:
In comparison with B-mode US, computer-aided MicroPure imaging can sensitively and quantitatively detect aggregate dissolution during effective ULT after only 3 months of treatment.
More Related Videos
10:02Quantitative SERS Detection of Uric Acid via Formation of Precise Plasmonic Nanojunctions within Aggregates of Gold Nanoparticles and Cucurbit[n]uril
Published on: October 3, 2020
09:51Methods for Analyzing the Impacts of Natural Uranium on In Vitro Osteoclastogenesis
Published on: January 30, 2018
Related Concept Videos
Urinary Tract Calculi III: Medical Management
Urinary Tract Calculi II: Pathophysiology and Clinical Manifestations
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Urinary Tract Calculi V: Nursing Management
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance