Related Experiment Video
Updated: Oct 14, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Diffusion Tensor Imaging in Characterization of Mediastinal Lymphadenopathy
Ahmed Abdel Khalek Abdel Razek1, Khaled Abdel Baky2, Eman Helmy1
1Department of Diagnostic Radiology. Mansoura University. faculty of medicine. Mansoura, Egypt.
Objective:
To determine the efficacy of diffusion-weighted MRI (DWI) and diffusion tensor imaging (DTI) in the characterization of mediastinal lymphadenopathy and the differentiation between malignant and benign lymph nodes (LNs).
Methods:
a retrospective evaluation of 58 patients with mediastinal lymphadenopathy that underwent DWI and DTI with calculation of apparent diffusion coefficient (ADC), fractional anisotropy (FA), and mean diffusivity (MD) values of LNs. Final diagnosis was made by the histopathology and proved metastatic (n = 21), lymphomatous (n = 14), granulomatous (n = 11) and reactive (n = 12) LNs.
Results:
Malignant mediastinal LNs had remarkably lower ADC and MD; (p = 0.001) and higher FA; (p = 0.001) than in benign LNs. The threshold of ADC, MD, and FA at (1.48, 1.32 × 10-3 mm2/s), (1.31, 1.33 × 10-3 mm2/s), (0.62, 0.52) to differentiate malignant from benign LNs has AUC of (0.89, 0.94), (0.96, 0.95), (0.72, 0.82), accuracy of (87%, 86%), (89%, 86%), (70%, 72%) by both observers respectively. The threshold of ADC, MD, and FA at (1.47, 1.32 × 10-3 mm2/s), (1.31, 1.3 × 10-3 mm2/s), (0.62, 0.67) used to differentiate metastatic from reactive LNs revealed AUC of (0.90, 0.94), (0.96, 0.96), (0.73, 0.77), accuracy of (87%, 81%), (87%, 81%), (72%, 66%) by both observers respectively. The mean ADC and MD values of metastatic LNs were statistically significant (p = 0.001) and (p = 0.002, 0.02) respectively when compared with that of lymphoma. The threshold of ADC, and MD (0.94, 0.97 × 10-3 mm2/s) and (0.87, 0.91 × 10-3 mm2/s) used to differentiates metastatic from lymphomatous nodes revealed AUC of (0.90, 0.91), (0.81, 0.74), an accuracy of (85%, 91%), (71%, 71%), by both observers respectively. The inter-class correlation between two observers for all nodes for ADC, MD and FA was r= 0.931, 0.956 and 0.885 respectively.
Conclusion:
Using ADC, MD, and FA can help in the characterization of mediastinal lymphadenopathy noninvasively.