Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

7.6K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
7.6K
Computed Tomography01:10

Computed Tomography

7.0K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
7.0K
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

88
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
88
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

96
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
96

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Clinical Outcomes of a Monofocal, Optimized, Aspheric IOL in Eyes with Different Degrees of Corneal Spherical Aberration.

Clinical ophthalmology (Auckland, N.Z.)·2026
Same author

Comparison of Reproducibility and Repeatability of Corneal Topography Measured by ATLAS 500 and ATLAS 9000 in Average Patient Population.

Clinical ophthalmology (Auckland, N.Z.)·2026
Same author

First Clinical Results of a Multicentric Prospective Study on the Visual Performance of Patients Implanted with a New Trifocal Aspheric Hydrophobic Intraocular Lens.

Clinical ophthalmology (Auckland, N.Z.)·2026
Same author

Comparison of two swept-source optical biometers in eyes with long axial length.

Frontiers in medicine·2026
Same author

Six-Month Visual and Patient-Reported Outcomes of a Biaspheric Trifocal IOL in Asian and European Cataract Patients: A Comparative Study.

Clinical ophthalmology (Auckland, N.Z.)·2025
Same author

Randomized comparative multicenter study assessing two dispersive viscosurgical devices for cataract surgery.

Journal of cataract and refractive surgery·2025

Related Experiment Video

Updated: Oct 14, 2025

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
12:22

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT

Published on: August 4, 2018

8.7K

Lens-vault analysis and its correlation with other biometric parameters using swept-source OCT.

Pedro Tañá-Rivero1, Ramón Ruiz-Mesa1, Salvador Aguilar-Córcoles1

  • 1Oftalvist Clinic, Alicante, Spain.

Journal of Optometry
|November 5, 2021
PubMed
Summary

Lens vault (LV) measurement is crucial in eye care. This study found LV correlates significantly with anterior chamber depth, axial length, volume, lens thickness, and age, suggesting its clinical importance.

Keywords:
Crystalline lens riseOptical coherence tomographySpur-to-spurSwept-source Fourier domainWhite-to-white

More Related Videos

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
07:44

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography

Published on: July 24, 2020

3.1K
Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
07:51

Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts

Published on: October 21, 2022

1.7K

Related Experiment Videos

Last Updated: Oct 14, 2025

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
12:22

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT

Published on: August 4, 2018

8.7K
In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
07:44

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography

Published on: July 24, 2020

3.1K
Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
07:51

Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts

Published on: October 21, 2022

1.7K

Area of Science:

  • Ophthalmology
  • Biomedical Optics
  • Anatomical Measurement

Background:

  • Accurate ocular biometry is essential for diagnosing and managing various eye conditions.
  • Lens vault (LV) is an understudied parameter in ocular anatomy.
  • High-resolution swept-source optical coherence tomography (SS-OCT) offers precise measurement capabilities.

Purpose of the Study:

  • To measure lens vault (LV) in healthy eyes using SS-OCT.
  • To investigate the correlation between LV and key ocular parameters.
  • To determine the clinical relevance of LV measurements in ophthalmology.

Main Methods:

  • Prospective study of 67 healthy Caucasian participants (mean age 41.9 ± 12.4 years).
  • Ocular measurements performed using the ANTERION SS-OCT device.
  • Parameters recorded: LV, anterior chamber depth (ACD), lens thickness (LT), axial length (AL), white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber volume (ACV), and spur-to-spur (STS) distance.

Main Results:

  • Mean LV was 0.26 ± 0.23 mm.
  • Significant negative correlations found between LV and ACD (R=-0.80), AL (R=-0.36), and ACV (R=-0.68).
  • Significant positive correlations found between LV and LT (R=0.67) and age (R=0.53).
  • No significant correlation observed between LV and WTW, CCT, or STS.

Conclusions:

  • Lens vault (LV) demonstrates significant correlations with multiple ocular parameters.
  • LV measurement, alongside other ocular metrics, is recommended for clinical practice.