Related Experiment Video
Updated: Oct 14, 2025

06:18
A Novel Method to Determine the Longitudinal Antibacterial Activity of Drug-Eluting Materials
Published on: March 3, 2023
1.6K
A New and Ecological Method to Quantify Vancomycin in Pharmaceutical Product by Infrared Spectrometry
Acta Chimica Slovenica
|November 5, 2021
Summary
A new, eco-friendly infrared spectrometry method quantifies vancomycin in pharmaceutical products. This fast, low-cost technique offers a sustainable alternative to existing analytical methods.
Area of Science:
- Analytical Chemistry
- Pharmaceutical Analysis
- Spectroscopy
Background:
- Existing literature lacks quantitative methods for vancomycin evaluation using infrared spectrometry.
- Infrared spectrometry offers a cleaner analytical alternative, minimizing solvent use and waste generation.
Purpose of the Study:
- To develop and validate a novel, ecological, cost-effective, and rapid infrared spectrometry method for vancomycin quantification.
- To establish a sustainable analytical approach for pharmaceutical product evaluation.
Main Methods:
- Utilized infrared spectrometry with potassium bromide (KBr).
- Focused on the spectral band between 1450-1375 cm⁻¹ for quantitative analysis.
- Validated the method for linearity, selectivity, precision, accuracy, and robustness.
Main Results:
- The method demonstrated linearity in the 1.0-2.0 mg/150 mg range with a high correlation coefficient (0.9994).
- Achieved excellent selectivity, precision (repeatability 2.29%, intermediate precision 3.12%), and accuracy (99.37% recovery).
- The method proved robust against variations in pellet strength, compression time, and KBr brand.
Conclusions:
- The developed infrared spectrometry method is an innovative and clean alternative for quantitative vancomycin analysis.
- The method is fast, user-friendly, economical, non-toxic, and generates minimal waste.
- This validated technique is suitable for routine analysis of vancomycin dosage forms, promoting sustainable pharmaceutical analysis.
Related Concept Videos
Infrared (IR) Spectroscopy: Overview
3.0K
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
3.0K
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
3.4K
Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material, molecules absorb light depending on the energy required for...
3.4K
UV–Vis Spectrometers
1.7K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.7K
Spectrophotometry: Introduction
5.4K
Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
5.4K
Applications of IR Spectroscopy: Overview
1.5K
The non-destructive nature and ability to provide valuable chemical information make IR spectroscopy a versatile technique with broad applications in various scientific and industrial fields. IR spectroscopy is commonly used to identify and characterize organic and inorganic compounds. It provides information about the functional groups present in a molecule and the bonding between atoms. This helps in the structural elucidation of compounds during organic synthesis, pharmaceutical research,...
1.5K
IR and UV–Vis Spectroscopy of Carboxylic Acids
4.7K
In IR spectroscopy of carboxylic acids, the C=O bond shows a characteristic band between 1710 and 1760 cm⁻¹, and the O–H bond exhibits a broad band between 2500 and 3300 cm⁻¹.
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
4.7K