Protocol for Microplastics Sampling on the Sea Surface and Sample Analysis
Published on: December 16, 2016
A comparison of spectroscopic analysis methods for microplastics: Manual, semi-automated, and automated Fourier
Young Kyoung Song1, Sang Hee Hong2, Soeun Eo2
1Risk Assessment Research Center, Korea Institute of Ocean Science and Technology, Geoje-shi 53201, South Korea.
Abstract:
This study was conducted to establish the best practice for microplastic analysis by reducing the time demand and human bias and comparing the characteristics of μ-FTIR and Raman techniques. A manual analysis, semi-automated method, and fully automatic identification method were compared. Fully automated identification took the shortest time to analyze a whole filter paper (Ø25 mm), but its false positive identification rate was 80 ± 15%. The semi-automated analysis using spectrum profiling was suitable for all aspects of microplastic analysis. It was less time consuming than the manual analysis (manual: 6.1 ± 0.8 h, semi-automated: 4.0 ± 0.6 h), and 22 ± 12% more microplastic particles were detected using the semi-automated method compared to the manual analysis due to the reduction in false negative results. Raman microscopy was suitable for small microplastic (>5 μm) identification, although the Raman analysis took nine times longer than the semi-automated analysis.
More Related Videos
05:31Sampling, Sorting, and Characterizing Microplastics in Aquatic Environments with High Suspended Sediment Loads and Large Floating Debris
Published on: July 28, 2018
05:05Quantification of Polybutylene Adipate Terephthalate-based Micro- and Nano-plastics from Soil Using Proton Nuclear Magnetic Resonance Spectroscopy
Published on: June 6, 2025
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Applications of IR Spectroscopy: Overview
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview