Getting the best GRIP on blood pressure control: Investigating a cost-effective isometric handgrip alternative
Jared J Richards1, Paula M van Wyk1, Cayla N Wood1
1Department of Kinesiology, Faculty of Human Kinetics, 8637University of Windsor, Windsor, Canada.
Objectives:
The World Health Organization emphasises the need for cost-effective alternative methods to lower blood pressure (BP). Endorsed nationally in HTN guidelines, isometric handgrip (IHG) training is an alternative method of BP control. The purpose of this study was to compare the BP, heart rate (HR) and rates of perceived exertion (RPE) responses between a bout of IHG training performed using the traditional computerized device and a more affordable, inflatable stress ball.
Methods:
Twenty healthy adults performed one bout (4, 2-min isometric contractions, with 1-min rests between each contraction at 30% maximal voluntary contraction) of IHG training using the traditional computerized device, and one bout with the inflatable stress ball. BP, HR, and RPE were recorded.
Results:
No statistically significant differences between devices were observed with HR, BP, and RPE (p < 0.05). However, average RPE for both devices ranged between 5 and 6 indicating that participants were rating 30% of their MVC, consistent with previous work.
Discussion:
The similar cardiovascular and psychophysical responses provide support for the potential use of this low individual- and provider-burden, cost-efficient IHG device, and lay the foundation for a future training study to test the hypothesis of benefit.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement