Related Experiment Video
Updated: Oct 14, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Collar Badge Lens Dose Equivalent Values among United States Physicians Performing Fluoroscopically Guided
David Borrego1, Craig Yoder2, Stephen Balter3
1Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland.
Purpose:
To describe the range of occupational badge dose readings and annualized dose records among physicians performing fluoroscopically guided interventional (FGI) procedures using job title information provided by the same 3 major medical institutions in 2009, 2012, and 2015.
Materials And Methods:
The Radiation Safety Office of selected hospitals was contacted to request assistance with identifying physicians in a large commercial dosimetry database. All entries judged to be uninformative of occupational doses to FGI procedure staff were excluded. Monthly and annualized doses were described with univariate statistics and box-and-whisker plots.
Results:
The dosimetry data set of interventional radiology staff contained 169 annual dose records from 77 different physicians and 698 annual dose records from 455 nonphysicians. The median annualized lens dose equivalent values among physicians (11.9 mSv; interquartile range [IQR], 6.9-20.0 mSv) was nearly 3-fold higher than those among nonphysician medical staff assisting with FGI procedures (4.0 mSv; IQR, 1.8-6.7 mSv) (P < .001). During the study period, without eye protection, 25% (23 of 93) of the physician annualized lens dose equivalent values may have exceeded 20 mSv; for nonphysician medical staff, this value may have been exceeded 3.5% (6 of 173) of the time. However, these values did not account for eye protection.
Conclusions:
The findings from this study highlight the importance of mitigating occupational dose to the eyes of medical staff, particularly physicians, performing or assisting with FGI procedures. Training on radiation protection principles, the use of personal protective equipment, and patient radiation dose management can all help ensure that the occupational radiation dose is adequately controlled.
More Related Videos