Related Experiment Video
Updated: Oct 14, 2025

Comparative Proteomic Analysis of Whole Kidney, Medulla, and Cortical Tubules in Diabetic Pathogenesis of Kidney Injury in Mice
Published on: May 2, 2025
Interobserver reproducibility of contrast-enhanced ultrasound in diabetic nephropathy
Lin Lin1, Yiru Wang1, Lin Yan1
1Department of Ultrasound, The First Medical Center, Chinese PLA General Hospital, Beijing, China.
Objective:
To investigate the interobserver reproducibility of contrast-enhanced ultrasound (CEUS) in patients with diabetic nephropathy.
Methods:
A total of 40 patients with diabetic nephropathy were enrolled in this retrospective study. We measured peak intensity (PEAK), time-to-peak (TP), area under the curve (AUC) and mean transit time (MTT) of renal CEUS in each patient. Each parameter was performed by two independent observers. The interobserver reproducibility was assessed using intraclass correlation coefficients (ICCs) with 95% confidence intervals (CIs) and Bland-Altman plots by mean difference with 95% limits of agreement (LOAs).
Results:
The parameters of the left and right kidneys showed moderate or good reliability. The best was the left kidney AUC parameters (ICC,0.945),with a 95% CI of 0.896-0.971.The Bland-Altman plots showed that the mean differences between the right renal parameters (PEAK, TP, AUC and MTT) obtained between the observers 1 and 2 were -6.63%,2.54%,-11.30%,-2.22%, and the 95% LOAs are -30.78 to 17.52%, -30.15 to 35.23%, -43.95 to 21.35%, -44.50 to 40.06%. While the left ones were -2.89%, 0.32%, -8.26%, 1.25% , and the 95% LOAs were -38.50 to 32.72%, -31.98 to 32.62%, -57.89 to 41.37%, -37.21 to 39.71%, respectively.
Conclusion:
Quantitative CEUS can show good interobserver reproducibility, which is better for the right kidney. It seems necessary to establish standardized techniques for obtaining contrast-enhanced quantitative analysis of renal blood perfusion.
Advances In Knowledge:
Quantitative assessment of renal perfusion by CEUS in patients with diabetic nephropathy provides diagnostic information. Furthermore, renal perfusion assessment in patients with diabetic nephropathy using CEUS has good reproducibility.
More Related Videos
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
08:22Combined Intravital Microscopy and Contrast-enhanced Ultrasonography of the Mouse Hindlimb to Study Insulin-induced Vasodilation and Muscle Perfusion
Published on: March 20, 2017
Related Concept Videos
Imaging Studies II: Ultrasonography
Imaging Studies VII: Vascular Imaging
Ultrasonography
During an ultrasonography procedure, a handheld device called...