Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Reproducibility of FDG PET/CT image-based cancer staging and standardized uptake values with simulated reduction of
Ryan D Niederkohr1, Stephen P Hayden1, James J Hamill2
1Department of Nuclear Medicine, Kaiser Permanente Santa Clara, CA, USA.
Abstract:
18F-fluorodeoxyglucose (FDG) PET/CT is widely used for oncologic imaging. This study aimed to evaluate, using data simulation, if reduction of injected FDG dose or PET acquisition time could be technically feasible when utilizing a sensitive commercial PET/CT imaging system, without sacrificing image quality, image-based staging accuracy, or standardized uptake value (SUV) accuracy. De-identified, standard of care oncologic FDG PET/CT datasets from 83 adults with lymphoma, lung carcinoma or breast carcinoma were retrospectively analyzed. All images had been acquired using clinical standard dose and acquisition time on a single PET/CT system. The list mode datasets were retrospectively software reprocessed to achieve undersampling of counts, thus simulating the effect of shorter PET acquisition time or lower injected FDG dose. The simulated reduced-count images were reviewed and compared with full-count images to assess and compare qualitative (subjective image quality, stage stability) and semi-quantitative (image noise, SUVmax stability, signal-to-noise and contrast-to-noise ratios within index lesions driving cancer stage) parameters. While simulated reduced-count images had measurably greater noise, there appeared to be no significant loss of image-based staging accuracy nor SUVmax reproducibility down to simulated FDG dose of 0.05 mCi/kg at continuous bed motion rate of 1.1 mm/sec. This retrospective simulation study suggests that a modest reduction of either injected FDG dose or emission scan time might be feasible in this limited oncologic population scanned on a single PET/CT system. Verification of these results with prospectively acquired images using actual low injected FDG activity and/or short imaging time is recommended.
More Related Videos
10:04Radionuclide-fluorescence Reporter Gene Imaging to Track Tumor Progression in Rodent Tumor Models
Published on: March 13, 2018
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...