Related Experiment Video
Updated: Oct 13, 2025

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Effect of contrast medium on treatment modalities planned with different photon beam energies: a planning study
Manindra Bhushan1,2, Deepak Tripathi2, Girigesh Yadav1
1Division of Medical Physics and Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India.
Background:
Routinely, patient's planning scans are acquired after administration of iodinized contrast media but they will be treated in the absence of that. Similarly, high energy photons have a better penetrating power, while low energy photons will result in tighter dose distribution and negligible neutron contamination. The aim of the study was to investigate a suitable photon beam energy in the presence of intravenous contrast medium.
Materials And Methods:
An indigenously made original-contrast (OC) phantom was mentioned as virtual-contrast (VC) and virtual-without-contrast (VWC) phantom were generated by assigning the Hounsfield Units (HU) to different structures. Intensity-modulated (IMRT) and volumetric-modulated-arc (VMAT) plans were generated as per criteria of the TG-119 protocol.
Results:
It was observed that the maximum dose to the spinal cord was better with 6 mega-voltage (MV) in IMRT. The coverage of Prostate PTV (PR PTV) was similar with all the photon energies and was comparable with TG-119, except for original-contrast (OC) phantom using the VMAT technique. Homogeneity-index (HI) was comparatively better for VMAT plans.
Conclusion:
The contrast CT images lower the dose to targets. IMRT or VMAT plans, generated on such CT images will be delivered with higher doses than evaluated. However, the overdose remains non-significant.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...