Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Cable Subjected to a Distributed Load01:24

Cable Subjected to a Distributed Load

842
The analysis of suspension bridges is a complex and critical process that involves multiple factors, including the shape and tension of the main cables. The main cables of suspension bridges are subjected to distributed loads, which result in changes in tensile forces and deformation of the cable. These loads must be carefully considered to ensure that the bridge is safe and capable of supporting the weight of different loads.
842
Cable: Problem Solving01:29

Cable: Problem Solving

397
When dealing with a cable that is fixed to two supports and subjected to uniform loading, it is crucial to determine the maximum tension in the cable. This process can be broken down into several key steps, as outlined below:
397
Cable Subjected to Its Own Weight01:13

Cable Subjected to Its Own Weight

584
Overhead power transmission lines rely on cables to carry electricity across large distances. To ensure the stability and functionality of these lines, it is crucial to understand the shape and tension experienced by the cables under the influence of their weight.
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
584
Cable Subjected to Concentrated Loads01:28

Cable Subjected to Concentrated Loads

1.0K
Flexible cables are commonly used in various applications for support and load transmission. Consider a cable fixed at two points and subjected to multiple vertically concentrated loads. Determine the shape of the cable and the tension in each portion of the cable, given the horizontal distances between the loads and supports.
1.0K
Energy Stored In A Coaxial Cable01:31

Energy Stored In A Coaxial Cable

1.7K
A coaxial cable consists of a central copper conductor used for transmitting signals, followed by an insulator shield, a metallic braided mesh that prevents signal interference, and a plastic layer that encases the entire assembly.
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic...
1.7K
Principle of Moments: Problem Solving01:30

Principle of Moments: Problem Solving

986
The principle of moments is a fundamental concept in physics and engineering. It refers to the balancing of forces and moments around a point or axis, also known as the pivot. This principle is used in many real-life scenarios, including construction, sports, and daily activities like opening doors and pushing objects.
One such scenario involves a pole placed in a three-dimensional system with a cable attached. When a tension is applied to the cable, the moment about the z-axis passing through...
986

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Experimental Investigation of the Effect of Nano Silica Fume on Durability of Concrete with Close-Packing Aggregate.

Materials (Basel, Switzerland)·2025
Same author

Design of a Concrete Shear Device and Investigation of the Shear Performance of New-to-Old Concrete Interfaces.

Materials (Basel, Switzerland)·2025
Same author

Optimizing High-Volume Fly Ash Mortar with Nano-SiO<sub>2</sub> and PVA Fibers: Performance and Microstructure.

Nanomaterials (Basel, Switzerland)·2025
Same author

A Cationic Amphiphilic AIE Polymer for Mitochondrial Targeting and Imaging.

Pharmaceutics·2023
Same author

De novo genome assembly and analyses of 12 founder inbred lines provide insights into maize heterosis.

Nature genetics·2023
Same author

Robo4 inhibits gamma radiation-induced permeability of a murine microvascular endothelial cell by regulating the junctions.

Cellular & molecular biology letters·2023

Related Experiment Video

Updated: Oct 13, 2025

Tension Gauge Tether Probes for Quantifying Growth Factor Mediated Integrin Mechanics and Adhesion
09:56

Tension Gauge Tether Probes for Quantifying Growth Factor Mediated Integrin Mechanics and Adhesion

Published on: February 11, 2022

2.7K

Fully Automated and Robust Cable Tension Estimation of Wireless Sensor Networks System.

Min Zhang1, Huating He1, Gengying Li1

  • 1College of Water Conservancy and Civil Engineering, South China Agricultural University, Guangzhou 510642, China.

Sensors (Basel, Switzerland)
|November 13, 2021
PubMed
Summary
This summary is machine-generated.

A new automated method accurately estimates cable tension using vibration data from wireless sensors. This robust technique eliminates manual intervention, enhancing structural health monitoring for cable-supported structures.

Keywords:
cable tension estimationfully automatedwireless sensor networks

More Related Videos

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
09:48

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping

Published on: November 7, 2016

12.2K
A Real-Time Wearable Electromyography Measurement System for Small Animals
05:00

A Real-Time Wearable Electromyography Measurement System for Small Animals

Published on: November 15, 2024

924

Related Experiment Videos

Last Updated: Oct 13, 2025

Tension Gauge Tether Probes for Quantifying Growth Factor Mediated Integrin Mechanics and Adhesion
09:56

Tension Gauge Tether Probes for Quantifying Growth Factor Mediated Integrin Mechanics and Adhesion

Published on: February 11, 2022

2.7K
Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
09:48

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping

Published on: November 7, 2016

12.2K
A Real-Time Wearable Electromyography Measurement System for Small Animals
05:00

A Real-Time Wearable Electromyography Measurement System for Small Animals

Published on: November 15, 2024

924

Area of Science:

  • Structural Engineering
  • Vibration Analysis
  • Wireless Sensor Networks

Background:

  • Accurate cable tension estimation is vital for structural health monitoring of cable-supported structures.
  • Identifying cable force from vibration data is a common method, relying on modal parameters like natural frequencies and frequency order.
  • Existing peak-picking methods in wireless sensor networks can be affected by factors impacting modal parameter accuracy.

Purpose of the Study:

  • To develop a fully automated and robust method for identifying cable tension from vibration data.
  • To overcome limitations of manual intervention and preprocessing in modal parameter identification for wireless sensor networks.
  • To improve the accuracy and reliability of cable tension estimation in structural health monitoring.

Main Methods:

  • A novel, fully automated method for modal parameter identification was developed.
  • The method was implemented on the Xnode wireless sensor system.
  • Validation was performed using data from the Jindo Bridge.

Main Results:

  • The wireless sensor system successfully distinguished power spectra, extracted peaks, and eliminated false frequencies automatically.
  • Frequency orders were determined without manual intervention or preprocessing.
  • Results for natural frequencies, orders, and cable tension force showed excellent agreement with a Matlab program method.

Conclusions:

  • The proposed automated method effectively and reliably estimates cable tension using the Xnode system.
  • This approach minimizes manual intervention, making it suitable for long-term monitoring.
  • The method is adaptable for other high-performance wireless sensor network systems for self-identification of cable tension.