Related Experiment Video
Updated: Oct 13, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
New Modes of Respiratory Support for the Premature Infant: Automated Control of Inspired Oxygen Concentration
Nelson Claure1, Eduardo Bancalari1
1Division of Neonatology, Department of Pediatrics, University of Miami Miller School of Medicine, Miami, FL, USA.
Insights
Extremely premature infants often experience unstable oxygen levels, risking lung and brain damage. Automated oxygen control systems aim to improve arterial oxygen saturation (Spo2) targeting, reducing harmful hyperoxemia and hypoxemia exposure.
Area of Science:
- Neonatal Medicine
- Respiratory Physiology
- Pediatric Critical Care
Background:
- Extremely premature infants frequently exhibit respiratory instability, leading to intermittent hypoxemia.
- Maintaining target arterial oxygen saturation (Spo2) ranges is challenging, with risks of both hyperoxemia and hypoxemia.
- Exposure to extreme Spo2 levels is linked to adverse outcomes, including lung damage, eye issues, and neurodevelopmental impairment.
Purpose of the Study:
- To evaluate the efficacy of automated systems in improving SpO2 targeting in extremely premature infants.
- To reduce the incidence of hyperoxemia and prolonged intermittent hypoxemia in this vulnerable population.
Main Methods:
- Development and implementation of automated control systems for inspired oxygen.
- Monitoring of SpO2 levels and clinical outcomes in extremely premature infants.
Main Results:
- Automated systems demonstrated improved consistency in maintaining target SpO2 ranges.
- Reduced exposure to extreme hyperoxemia and prolonged hypoxemia episodes was observed with automated control.
Conclusions:
- Automated inspired oxygen control systems show promise for enhancing respiratory support in extremely premature infants.
- These systems may mitigate risks associated with unstable oxygenation, potentially improving long-term outcomes.
Abstract:
Most extremely premature infants have respiratory instability that can manifest as frequent episodes of intermittent hypoxemia. Although caregivers target clinically recommended ranges of arterial oxygen saturation (oxygen saturation as measured by pulse oximetry [Spo2]), consistent maintenance of these ranges is not always achieved. Excessive administration of supplemental oxygen combined with limited staff resources increases exposure to extreme Spo2 levels. In this population, exposure to hyperoxemia and prolonged episodes of intermittent hypoxemia have been associated with damage to the eye and lung and impaired neurodevelopment. To improve Spo2 targeting, various systems for automated control of inspired oxygen have been developed recently.
More Related Videos
05:45Delivery of In Vivo Acute Intermittent Hypoxia in Neonatal Rodents to Prime Subventricular Zone-derived Neural Progenitor Cell Cultures
Published on: November 2, 2015
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...