Related Experiment Video
Updated: Oct 13, 2025

A Filter-based Surface Enhanced Raman Spectroscopic Assay for Rapid Detection of Chemical Contaminants
Published on: February 19, 2016
Hazardous Gas Detection by Cavity-Enhanced Raman Spectroscopy for Environmental Safety Monitoring
Pinyi Wang1, Weigen Chen1, Jianxin Wang1
1Chongqing University State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing 400044, China.
Abstract:
We demonstrate the practicability of cavity-enhanced Raman spectroscopy (CERS) with a folded multipass cavity as a unique tool for the detection of hazardous gases in the atmosphere. A four-mirror Z-sharped multipass cavity results in a greatly extended laser-gas interaction length to improve the Raman signal intensity of gases. For Raman intensity maximization, the optimal number of intracavity beams of a single reflection cycle is calculated and then the cavity parameters are designed. A total of 360 intracavity beams are realized, which are circulated four times in the cavity based on the polarization. ppb-Level Raman gas sensing at atmospheric pressure for several typical explosive gases and toxic gases in ambient air, including hydrogen (H2), methane (CH4), carbon monoxide (CO), hydrogen sulfide (H2S), and chlorine (Cl2), is achieved at 300 s exposure time. Our CERS apparatus, which can detect multiple gases simultaneously with ultrahigh sensitivity and high selectivity, is powerful for detecting hazardous gases in the atmosphere, and it has excellent potential for environmental safety monitoring.
More Related Videos
07:52A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...