Related Experiment Video
Updated: Oct 13, 2025

Robot-assisted Total Mesorectal Excision and Lateral Pelvic Lymph Node Dissection for Locally Advanced Middle-low Rectal Cancer
Published on: February 12, 2022
Ex Vivo Comparison of Efficiency, Safety, and Surgeon Satisfaction in Four Commercial Morcellators
Matthew S Lee1, Mark Assmus1, Lauren F Cooley1
1Department of Urology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
Abstract:
Holmium laser enucleation of the prostate (HoLEP) is a size-independent treatment option for the management of benign prostatic hypertrophy. Although advancements in laser technology have led to clinical improvements in the enucleation portion of HoLEP, the morcellation aspect of HoLEP is often the rate-limiting step. We sought to compare efficiency and surgeon satisfaction in four commercial morcellators. This was an ex vivo study comparing four commercial morcellators: the Wolf Piranha™, the Lumenis VersaCut™, the JenaSurgical MultiCut Solo™, and the Hawk™ Morcellator. Four surgeons with significant experience performing HoLEPs participated. Surgeons tested each device to morcellate two different prostate models (1) morcellating as much microwave-cooked chicken breast in 10 minutes and (2) timed morcellation of bull testicles. Surgeons completed subjective surveys after each morcellator trial. Objective outcomes included the following: morcellation efficiency (g/min morcellated) and aspiration power (time to aspirate 1 L of saline). Means of continuous variables were compared using analysis of variance. Categorical variables were compared using chi-square tests. Statistical analyses were performed using SAS 9.4 (2019). Comparing subjective outcomes, the Piranha™ was chosen as the safest morcellator (p = 0.0058). The least safe morcellator was thought to be the MultiCut by 75% of surgeons (p = 0.046). The Piranha™ was chosen as the most effective morcellator by 75% of surgeons (p = 0.046). Comparing objective parameters between the morcellators, the Piranha™ had the fastest aspiration time (43.50 ± 10.34 seconds, p = 0.0116). There were no significant differences in morcellation efficiency when using chicken breast (p = 0.3096). However, when comparing the morcellation efficiency using bull testicles, the Piranha™ had the highest efficiency at 39.68 ± 3.57 g/min (p = 0.0268). In this ex vivo study comparing four different commercially available morcellators, the Piranha™ had the highest aspiration power. No significant differences were found in morcellation efficiency using microwave-cooked chicken breast. The Piranha™ was felt to be the safest and most effective morcellator.
More Related Videos
05:46Introduction of Intracapsular Rotary-cut Procedures IRCP: A Modified Hysteromyomectomy Procedures Facilitating Fertility Preservation
Published on: January 17, 2019
03:54A New Ex Vivo Model for the Evaluation of Endoscopic Submucosal Injection Material Performance
Published on: October 19, 2018