Related Experiment Video
Updated: Oct 13, 2025

A Retrograde Implantation Approach for Peritoneal Dialysis Catheter Placement in Mice
Published on: July 20, 2022
Understand the difference between clinical measured ultrafiltrationand real ultrafiltration in peritoneal dialysis
Zanzhe Yu1, Zhuqing Wang1, Qin Wang1
1Department of Nephrology, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China.
Background:
It has been noticed for years that ultrafiltration (UF) is important for survival in peritoneal dialysis. On the other hand, precise and convenient UF measurement suitable for patient daily practice is not as straight forward as it is to measure UF in the lab. Both overfill and flush before fill used to be source of measurement error for clinical practice. However, controversy finding around UF in peritoneal dialysis still exists in some situation. The current study was to understand the difference between clinical measured UF and real UF. The effect of evaporation and specific gravity in clinical UF measurement were tested in the study.
Methods:
Four different brands of dialysate were purchased from the market. The freshest dialysate available in the market were intentionally picked. The bags were all 2 L, 2.5% dextrose and traditional lactate buffered PD solution. They were stored in four different conditions with controlled temperature and humidity. The bags were weighted at baseline, 6 months and 12 months of storage. Specific gravity was measured in mixed 24 h drainage dialysate from 261 CAPD patients when they come for their routine solute clearance test.
Results:
There was significant difference in dialysate bag weight at baseline between brands. The weight declined significantly after 12 month's storage. The weight loss was greater in higher temperature and lower humidity. The dialysate in non-PVC package lose less weight than PVC package. The specific gravity of dialysate drainage was significantly higher than pure water and it was related to dialysate protein concentration.
Conclusion:
Storage condition and duration, as well as the type of dialysate package have significant impact in dialysate bag weight before use. Evaporation is likely to be the reason behind. The fact that specific gravity of dialysate drainage is higher than 1 g/ml overestimates UF in manual exchanges, which contributes to systemic measurement error of ultrafiltration in CAPD.
Trial Registration:
ClinicalTrials.gov ID: NCT03864120 (March 8, 2019) (Understand the Difference Between Clinical Measured Ultrafiltration and Real Ultrafiltration).
More Related Videos
07:11Surgical Techniques for Catheter Placement and 5/6 Nephrectomy in Murine Models of Peritoneal Dialysis
Published on: July 19, 2018
10:19Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016
Related Concept Videos
Peritoneal Dialysis I: Introduction and Procedure
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis
Peritoneal Dialysis III: Nursing Management
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy