Effect of computed tomography scanner location on time-to-computed tomography in the emergency department: A before
C J Cabilan1, Robert Eley1,2, Andrew Staib1,2
1Emergency Department, Princess Alexandra Hospital, Brisbane, Queensland, Australia.
Objectives:
To compare time metrics associated with a temporary disruption to ED computed tomography (CT) scanner location from adjacent to the ED with direct access from resuscitation rooms, to a location remote to the ED.
Methods:
A retrospective before and after study was conducted in a public metropolitan ED with over 66 000 presentations annually. Time-to-CT metrics, operational time metrics and ED length of stay were extracted and analysed from presentations between October 2020 and January 2021.
Results:
There were 3031 CT scans during the study period. Overall, the disruption was associated with a significant 27-36 min delay (P < 0.01) in time-to-CT start; these delays were also observed in a subset of trauma patients. In a subset of presumed stroke patients, time-to-brain perfusion was significantly delayed by up to 10 min (P < 0.01). There was a 14% (P < 0.01) greater demand for operational services and a time imposition of up to 8 min (P < 0.01) to transport patients to or from CT scanning when the CT scanner was located away from the ED. ED length of stay was consistent at all time points.
Conclusion:
Although rapid, proximate access to CT scanning is often considered desirable in terms of the management of trauma and other time-critical emergencies, the wider time and resource implications demonstrated in this study suggest a potential broader benefit to co-located CT scanning in ED. Our experience could be considered in future re-design of EDs.
More Related Videos
09:52Setting Up a Stroke Team Algorithm and Conducting Simulation-based Training in the Emergency Department - A Practical Guide
Published on: January 15, 2017
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET