Purpose:
Comparison of puncture deviation and puncture duration between computed tomography (CT)- and C-arm CT (CACT)-guided puncture performed by residents in training (RiT).
Methods:
In a cohort of 25 RiTs enrolled in a research training program either CT- or CACT-guided puncture was performed on a phantom. Prior to the experiments, the RiT's level of training, experience playing a musical instrument, video games, and ball sports, and self-assessed manual skills and spatial skills were recorded. Each RiT performed two punctures. The first puncture was performed with a transaxial or single angulated needle path and the second with a single or double angulated needle path. Puncture deviation and puncture duration were compared between the procedures and were correlated with the self-assessments.
Results:
RiTs in both the CT guidance and CACT guidance groups did not differ with respect to radiologic experience (p = 1), angiographic experience (p = 0.415), and number of ultrasound-guided puncture procedures (p = 0.483), CT-guided puncture procedures (p = 0.934), and CACT-guided puncture procedures (p = 0.466). The puncture duration was significantly longer with CT guidance (without navigation tool) than with CACT guidance with navigation software (p < 0.001). There was no significant difference in the puncture duration between the first and second puncture using CT guidance (p = 0.719). However, in the case of CACT, the second puncture was significantly faster (p = 0.006). Puncture deviations were not different between CT-guided and CACT-guided puncture (p = 0.337) and between the first and second puncture of CT-guided and CACT-guided puncture (CT: p = 0.130; CACT: p = 0.391). The self-assessment of manual skills did not correlate with puncture deviation (p = 0.059) and puncture duration (p = 0.158). The self-assessed spatial skills correlated positively with puncture deviation (p = 0.011) but not with puncture duration (p = 0.541).
Conclusion:
The RiTs achieved a puncture deviation that was clinically adequate with respect to their level of training and did not differ between CT-guided and CACT-guided puncture. The puncture duration was shorter when using CACT. CACT guidance with navigation software support has a potentially steeper learning curve. Spatial skills might accelerate the learning of image-guided puncture.
Key Points:
· The CT-guided and CACT-guided puncture experience of the RiTs selected as part of the program "Researchers for the Future" of the German Roentgen Society was adequate with respect to the level of training.. · Despite the lower collective experience of the RiTs with CACT-guided puncture with navigation software assistance, the learning curve regarding CACT-guided puncture may be faster compared to the CT-guided puncture technique.. · If the needle path is complex, CACT guidance with navigation software assistance might have an advantage over CT guidance..
Citation Format:
· Meine TC, Hinrichs JB, Werncke T et al. Phantom study for comparison between computed tomography- and C-Arm computed tomography-guided puncture applied by residents in radiology. Fortschr Röntgenstr 2022; 194: 272 - 280.
More Related Videos
09:29Author Spotlight: Improving Percutaneous Vertebroplasty Surgical Accuracy and Efficiency Through Advanced Puncture Techniques
Published on: August 9, 2024
05:04Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET