Related Experiment Video
Updated: Oct 12, 2025

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
The appearance of magnetic susceptibility objects in SWI phase depends on object size: Comparison with QSM and CT
Hong Xie1, Hangwei Zhuang2, Yihao Guo3
1Department of Radiology, The First College of Clinical Medical Science, Three Gorges University, Yichang, Hubei Province, China.
Purpose:
Tissue magnetic susceptibility sign can potentially be detected on susceptibility weighted imaging (SWI) phase (SW-P). This study aims to investigate its performance for depicting brain susceptibility structures.
Methods:
A simulation was performed to depict magnetic susceptibility structures of various geometries on SW-P and quantitative susceptibility mapping (QSM). Brain MRI was performed on 25 subjects using SWI on a 3 T MRI system. QSM was generated from the same data. SW-P and QSM were analyzed according to radiological assessment for depicting globus pallidus nuclei, optic radiation white matter tracts, and lateral ventricular choroid plexus calcifications. In 11 of these subjects, CT was available and correlated with SW-P and QSM to assess their performance in quantifying calcifications in the choroid plexus.
Results:
In simulation, the appearance of a sphere on SW-P ranged from centric nodule to mixed positive and negative values as the diameter increased. Large cylinders also appeared as mixed positive and negative values. In comparison, QSM correctly depicted the susceptibility distribution of all magnetic structures. On human brain images, SW-P depicted the globus pallidus and optic radiation with mixed positive and negative values, consistent with simulation, and small choroid plexus calcifications as either mixed positive and negative values or as centric nodules; QSM depicted all structures as solid structures with the expected signs. For measuring calcification in the choroid plexus, QSM vs CT linear regression had a higher coefficient of determination compared to SW-P vs CT and SW-P vs QSM.
Conclusion:
Appearance of susceptibility sources on SW-P changes with object size. This problem can be overcome using QSM.
More Related Videos
06:53Author Spotlight: Magnetometric Characterization of Intermediates in the Solid-State Electrochemistry of Redox-Active Metal-Organic Frameworks
Published on: June 9, 2023
07:42Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains
Published on: July 20, 2022
Related Concept Videos
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Atomic Nuclei: Magnetic Resonance
Magnetic Resonance Imaging
NMR Spectrometers: Resolution and Error Correction