Related Experiment Video
Updated: Oct 12, 2025

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Does recorded oximetry utilizing a consensus-based algorithm compare to polysomnography in discontinuing home oxygen
Heather White1,2, Celia Sobelman3, Ted Kremer2
1Division of Neonatology, University of Massachusetts Medical School, Worcester, Massachusetts, USA.
Background:
Approximately a third of all extremely preterm infants diagnosed with bronchopulmonary dysplasia will require home oxygen therapy (HOT). Lack of consensus-based guidelines has led to significant variability in outpatient HOT management in the United States. A common assessment performed before discontinuing oxygen is a formal polysomnogram (PSG). PSGs are potentially undesirable due to cost, lack of convenient access, and parental stress, so alternative testing to determine the optimal timing of safe oxygen discontinuation are needed.
Methods:
We compared nocturnal recorded home oximetry (RHO) with PSG data in a cohort of patients from the RHO trial for patients who had recordings performed simultaneously to or within 24 h of their PSG. The RHO trial was a randomized, unblinded, multi-center trial comparing two oxygen management strategies. Parameters of oxygenation were compared between PSG and RHO, and nonoximegtry findings from the PSG that changed clinical management were identified.
Results:
A total of 53 infants randomized to obtain a PSG as part of the RHO trial (55%) completed a PSG, and of those, 32 (64%) completed both a PSG with comparison RHO. There were more white infants in both groups than other races and ethnicities. Bland-Altman analysis showed a strong agreement of oxygen saturation time below 90% SpO2 between PSG and RHO results (slope = 1.014, p = 0.24). Results agreed in 96% of cases.
Conclusion:
RHO is a safe and effective alternative to PSG to assist in determination of discontinuing HOT in infants with BPD without other risks for sleep-disordered breathing.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...