Related Experiment Video
Updated: Oct 12, 2025

Myocardial Infarction and Functional Outcome Assessment in Pigs
Published on: April 25, 2014
Safety evaluation of high-risk myocardial micro-biopsy in a swine model
Arvin Chireh1, Mikael Sandell1,2,3, Rikard Grankvist1
1Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.
Abstract:
The objective of the study was to investigate the safety profile of high-risk micro-endomyocardial biopsy (micro-EMB) compared to conventional EMB in a large animal model. Twenty pigs were subjected to a maximum of 30 consecutive biopsies, including sampling from the free ventricular wall, with either micro-EMB (n = 10) or conventional EMB (n = 10). There were no major complications in the micro-EMB group (0/10), compared to six major complications in the EMB group (6/10; p = 0.003). Survival analysis further highlighted these differences (p = 0.004). There were significantly higher volumes of pericardial effusion in the EMB group (p = 0.01). The study shows a safety advantage of micro-EMB compared to standard EMB in the experimental high-risk circumstances investigated in this animal study. These results indicate enhanced possibilities to collect samples from sensitive areas by using the micro-EMB technique instead of standard EMB.