Dose calculation and reporting with a linear Boltzman transport equation solver in vertebral SABR
Nicholas Hardcastle1,2,3, Jeremy Hughes4, Shankar Siva4,5
1Physical Sciences, Peter MacCallum Cancer Centre, 305 Grattan St, Melbourne, VIC, 3012, Australia. nick.hardcastle@Petermac.org.
Abstract:
Vertebral Stereotactic ablative body radiotherapy (SABR) involves substantial tumour density heterogeneities. We evaluated the impact of a linear Boltzmann transport equation (LBTE) solver dose calculation on vertebral SABR dose distributions. A sequential cohort of 20 patients with vertebral metastases treated with SABR were selected. Treatment plans were initially planned with a convolution style dose calculation algorithm. The plan was copied and recalculated with a LBTE algorithm reporting both dose to water (Dw) or dose to medium (Dm). Target dose as a function of CT number, and spinal cord dose was compared between algorithms. Compared with a convolution algorithm, there was minimal change in PTV D90% with LBTE. LBTE reporting Dm resulted in reduced GTV D50% by (mean, 95% CI) 2.2% (1.9-2.6%) and reduced Spinal Cord PRV near-maximum dose by 3.0% (2.0-4.1%). LBTE reporting Dw resulted in increased GTV D50% by 2.4% (1.8-3.0%). GTV D50% decreased or increased with increasing CT number with Dm or Dw respectively. LBTE, reporting either Dm or Dw resulted in decreased central spinal cord dose by 8.7% (7.1-10.2%) and 7.2% (5.7-8.8%) respectively. Reported vertebral SABR tumour dose when calculating with an LBTE algorithm depends on tumour density. Spinal cord near-maximum dose was lower when using LBTE algorithm reporting Dm, which may result in higher spinal cord doses being delivered than with a convolution style algorithm. Spinal cord central dose was significantly lower with LBTE, potentially reflecting LBTE transport approximations.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Maxwell-Boltzmann Distribution: Problem Solving
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Compartment Models: Single-Compartment Model
Drug Accumulation During Multiple Dosing: Repetitive IV Injections
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...