Preservation of vapor samples on adsorbent alumina capillaries and implications for field sampling
Megan E Harries1, Kavita M Jeerage1
1Applied Chemicals and Materials Division, National Institute of Standards and Technology (NIST), 325 Broadway, Boulder, CO 80305, United States.
Abstract:
Dynamic vapor microextraction (DVME) is a vapor preconcentration method that employs a capillary trap coated with an adsorbent, followed by solvent elution to recover the sample. DVME has been developed for applications in the laboratory, including highly precise vapor pressure measurements, and in the field. When vapor collection is conducted outside the laboratory, samples must almost always undergo some interval of storage representing the time between collection and analysis. This interval may be hours, days, or longer, depending on the situation. Regardless, in all situations there must be confidence that the integrity of the samples is maintained until processing and analysis. In this paper, we present results of two studies that tested the stability of a 50% weathered gasoline headspace sample on alumina PLOT (porous layer open tubular) capillaries stored at room temperature for periods from 24 h up to 20 wk. We used principal component analysis (PCA) to reduce the dimensionality of the chromatographic and mass spectral data and elucidate trends in stability with respect to the complex sample's range of hydrocarbon classes and molecular weights. Both analyses identified changes over storage periods of six weeks or more. The hydrocarbon class analysis, which used selected ion monitoring (SIM) data as input, proved more sensitive to changes over shorter storage periods. Sample integrity was preserved for at least 24 h, but losses, especially of high-volatility compounds, occurred by 168 h (7 d). Near total loss of sample occurred by 20 wk. These findings, which are specific to the sample, adsorbent, and storage conditions, will guide choices in experimental and instrumental design to ensure that data from future field studies is reliable.
More Related Videos
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Volatilization
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...