Anterior-Lateral Versus Anterior-Posterior Electrode Position for Cardioverting Atrial Fibrillation
Anders Sjørslev Schmidt1,2, Kasper Glerup Lauridsen1,2, Dorthe Svenstrup Møller3
1Department of Internal Medicine, Randers Regional Hospital, Denmark (A.S.S., K.G.L., H.R., B.L.).
Background:
Smaller randomized studies have reported conflicting results regarding the optimal electrode position for cardioverting atrial fibrillation. However, anterior-posterior electrode positioning is widely used as a standard and believed to be superior to anterior-lateral electrode positioning. Therefore, we aimed to compare anterior-lateral and anterior-posterior electrode positioning for cardioverting atrial fibrillation in a multicenter randomized trial.
Methods:
In this multicenter, investigator-initiated, open-label trial, we randomly assigned patients with atrial fibrillation scheduled for elective cardioversion to either anterior-lateral or anterior-posterior electrode positioning. The primary outcome was the proportion of patients in sinus rhythm after the first shock. The secondary outcome was the proportion of patients in sinus rhythm after up to 4 shocks escalating to maximum energy. Safety outcomes were any cases of arrhythmia during or after cardioversion, skin redness, and patient-reported periprocedural pain.
Results:
We randomized 468 patients. The primary outcome occurred in 126 patients (54%) assigned to the anterior-lateral electrode position and in 77 patients (33%) assigned to the anterior-posterior electrode position (risk difference, 22 percentage points [95% CI, 13-30]; P<0.001). The number of patients in sinus rhythm after the final cardioversion shock was 216 (93%) assigned to anterior-lateral electrode positioning and 200 (85%) assigned to anterior-posterior electrode positioning (risk difference, 7 percentage points [95% CI, 2-12]). There were no significant differences between groups in any safety outcomes.
Conclusions:
Anterior-lateral electrode positioning was more effective than anterior-posterior electrode positioning for biphasic cardioversion of atrial fibrillation. There were no significant differences in any safety outcome. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03817372.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Cardiopulmonary Resuscitation III: AED Use
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias