Related Experiment Video
Updated: Oct 12, 2025

Augmented Reality Navigation-Guided Core Decompression for Osteonecrosis of Femoral Head
Published on: April 12, 2022
Can the need for soft tissue release in total knee replacement be predicted pre-operatively? A study based on
Daniel Hernandez-Vaquero1, Alfonso Noriega-Fernandez2, Sergio Roncero-Gonzalez2
1Department of Orthopedic Surgery, School of Medicine, University of Oviedo, Julian Claveria, s/n, 33006, Oviedo, Spain. dhernandez@uniovi.es.
Introduction:
In complex and deformed knees, soft tissue release (STR) is required to obtain symmetry in the femorotibial gap. The objective of this study was to attempt to predict the need for soft tissue release using surgical navigation in total knee replacement (TKR).
Methods:
Prospective and non-randomized study. One hundred thirty knees. At the start of navigation, an attempt was made to correct the femorotibial mechanical axis by applying force to the medial or lateral side of the knee (varus-valgus stress angle test). A gap balanced technique with computer-assisted surgery (CAS) was performed in all cases. The ligaments were tensioned, and using CAS visualization and control, progressive STR was performed in the medial or lateral side until a symmetry of the femorotibial gap was achieved.
Results:
Eighty-two patients had a varus axis ≥ 3° and 38 had a valgus axis (P < 0.001). STR was performed under navigation control in 38.5% of cases, lateral release (LR) in 12 cases, and medial release (MR) in 38 cases. After performing the varus-valgus stress angle test (VVSAT), the axis of 0° could be restored at some point during the manoeuvre in 28 cases. STR was required in 44.6% of varus cases and 27% of valgus cases (P = 0.05). A significant relationship was found between the previous deformity and the need for MR (P < 0.001) or LR (P = 0.001). STR was more common in male patients (P = 0.002) and as obesity increased.
Conclusion:
This study shows that pre-operative factors favouring the need to perform STR in a TKR implant can be defined.