Related Experiment Video
Updated: Oct 12, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Potential of spiral breast computed tomography to increase patient comfort compared to DM
Matthias Wetzl1, Evelyn Wenkel1, Matthias Dietzel1
1Department of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054 Erlangen, Germany.
Purpose:
To intra-individually compare patient comfort of spiral breast computed tomography (SBCT) versus digital mammography (DM).
Method:
This prospective IRB approved study included 79 patients undergoing both SBCT and DM for the assessment of BI-RADS 4 - 6 lesions. Following SBCT and DM patients answered a standardized questionnaire regarding "Overall patient comfort" and "Pain" on a 5-point Likert Scale. On the same Likert Scale, experienced radiologic technicians rated the workflow of the SBCT regarding patients' "Mobility", ease of patient "Positioning", patients' adherence to the examination ("Compliance") and expected image quality. Visibility of fibroglandular tissue in SBCT was independently rated by two breast radiologists on a 10-point Likert Scale. Subgroups stratified by menopausal status and body mass index (BMI) were analyzed.
Results:
Patients reported significantly lower pain during SBCT (4.73 ± 0.57) compared to DM (4.09 ± 0.90; P < 0.01). This effect was independent from BMI. However, pain reduction by SBCT was most pronounced in premenopausal (SBCT vs. DM: 4.79 ± 0.50 vs. 3.89 ± 0.99) compared to postmenopausal patients (4.71 ± 0.77 vs. 4.20 ± 0.89). Overall patient comfort in premenopausal patients tended to be higher in SBCT compared to DM (P = 0.08). Radiologic technicians rated the SBCT procedure generally as positive (average: 4.62 ± 0.56). Coverage of fibroglandular tissue in SBCT was generally high (9.82 ± 0.43) and interrater agreement was good (κ = 0.77).
Conclusions:
Patients experience less pain during spiral breast computed tomography compared to DM, especially in premenopausal women. Imaging is feasible at a high level of anatomical breast coverage and without problems with the clinical workflow.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT