Related Experiment Video
Updated: Sep 2, 2026

Clinical Imaging of Microwave Mammography
Published on: November 14, 2025
Breast MRI With Abbreviated Reading Protocol as Additional Evaluation Tool for Suspicious Microcalcifications in a
Patrik Pöschke1,2,3, Evelyn Wenkel4,5, Carla Schulmeyer6,2,3
1Department of Gynecology and Obstetrics, Erlangen University Hospital, Comprehensive Cancer Center Erlangen-EMN (CCC ER-EMN)/Friedrich Alexander University of Erlangen-Nuremberg (FAU), Erlangen, Germany; patrik.poeschke@uk-erlangen.de.
Background/Aim:
Biopsy of suspicious microcalcifications (MC) detected in breast cancer screening yields benign results in the majority of cases, resulting in a substantial number of avoidable interventions. While magnetic resonance imaging (MRI) demonstrates high accuracy for invasive breast cancer, its diagnostic value for precancerous lesions remains uncertain - particularly in average-risk screening populations. This study aimed to assess the diagnostic performance of an abbreviated breast MRI reading protocol in a screening-like cohort.
Patients And Methods:
In this prospective single-center study, 58 women (mean age 58±24 years) with 59 suspicious MC on full-field digital mammography (FFDM) were included. A total of 68 lesions underwent histopathological verification. MRI datasets were independently assessed by four radiologists (5-15 years of experience), blinded to mammographic findings, using a standardized abbreviated protocol including maximum intensity projection (MIP), early post-contrast subtraction, and native images.
Results:
Among 59 microcalcification lesions, 21 were malignant and 38 benign. Sensitivity ranged from 74% to 83%, specificity from 58% to 83%, positive predictive value from 56% to 75%, negative predictive value from 83% to 86%, and accuracy from 68% to 81%. No invasive carcinomas were missed by any reader. False-negative findings were exclusively ductal carcinoma in situ (DCIS). Mean reading time ranged from 1 min 42 sec to 3 min 26 s. MIP-only evaluation demonstrated markedly lower sensitivity (48-52%) despite higher specificity (83-94%). Interreader agreement for the final recall decision was moderate (Fleiss' κ=0.47), with pairwise Cohen's κ values ranging from 0.40 to 0.53.
Conclusion:
Abbreviated breast MRI is a feasible and time-efficient approach with consistent diagnostic performance across readers for evaluating suspicious MC, further evaluation as screening tool is needed. MIP-only evaluation, does not appear to provide sufficient diagnostic reliability.
More Related Videos
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Magnetic Resonance Imaging
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies IV: Magnetic Resonance Imaging

