Related Experiment Video
Updated: Oct 12, 2025

Quantification of Fungal Colonization, Sporogenesis, and Production of Mycotoxins Using Kernel Bioassays
Published on: April 23, 2012
Evaluating the Performance of Lateral Flow Devices for Total Aflatoxins with Special Emphasis on Their Robustness
Barbara Cvak1,2, Benedikt Warth3, Joseph Atehnkeng4
1University of Natural Resources and Life Sciences, Vienna, Department of Agrobiotechnology, IFA-Tulln, Institute of Bioanalytics and Agro-Metabolomics, Konrad-Lorenz-Strasse 20, 3430 Tulln an der Donau, Austria.
Abstract:
As aflatoxins are a global risk for humans and animals, testing methods for rapid on-site screening are increasingly needed alongside the standard analytical laboratory tools. In the presented study, lateral flow devices (LFDs) for rapid total aflatoxin screening were thoroughly investigated with respect to their matrix effects, cross-reactivity, their performance under harsh conditions in Sub-Saharan Africa (SSA), and their stability, as well as when compared with liquid chromatography-tandem mass spectrometry (LC-MS/MS). To analyze the matrix effects, qualitative test kits offering a certain cutoff level were used to screen different nut samples. In addition, these tests were challenged on their cross-reactivity with 230 fungal toxins and metabolites. Furthermore, the resulting measurements performed under harsh tropical conditions (up to 38.4 °C and 91% relative humidity) in SSA, specifically Burkina Faso and Mozambique, were compared with the results from a well-established and validated LC-MS/MS-based reference method. The comparison of the on-site LFD results with the reference method showed a good agreement: 86.4% agreement, 11.8% non-agreement, and 1.8% invalid test results. To test the robustness of the cutoff tests, short- and long-term stability testing was carried out in Mozambique and Nigeria. For both experiments, no loss of test performance could be determined. Finally, a subset of African corn samples was shipped to Austria and analyzed under laboratory conditions using semiquantitative aflatoxin tests. A good correlation was found between the rapid strip tests and the LC-MS/MS reference method. Overall, the evaluated LFDs showed satisfying results regarding their cross-reactivity, matrix effects, stability, and robustness.
More Related Videos
10:24Author Spotlight: Quantification of Aflatoxins and Phytoalexins in Peanut Seeds to Identify Genetic Resistance Against Aspergillus
Published on: April 19, 2024
09:21Inhibition of Aspergillus flavus Growth and Aflatoxin Production in Transgenic Maize Expressing the α-amylase Inhibitor from Lablab purpureus L.
Published on: February 15, 2019