Effect of Roller Pump Pulse in the Arterial Needle Area during Hemodialysis

Milos Kasparek1, Ludmila Novakova2, Jan Malik3

  • 1Department of Fluid Dynamics and Thermodynamics, Faculty of Mechanical Engineering CTU in Prague, Technická 4, 160 00 Prague, Czech Republic.

Vascular access is a lifeline for hemodialysis patients. Its lifetime is affected by many hemodynamic factors such as pressure, flow regime and wall shear stress. During hemodialysis, changes in hemodynamic parameters occur due to the flow from needles inserted into the vascular system. Primarily, there is a change in shear stress that affects the vascular wall. Pathological effects of high or low WSS are known. The effect of jet from a venous needle on hemodynamics parameters was studied, but the influence of the arterial needle on hemodynamics parameters is not sufficiently studied. To understand its possible effects, we performed in vivo and in vitro studies. Methods. In vivo experiment: The existence of flow reversal around the suction needle was visualized in a group of 12 randomly selected patients using ultrasound velocity profiling (Doppler ultrasonography) during hemodialysis. In vitro experiment: The flow field was measured using the stereo particle image velocimetry method (stereo PIV). Two regimes were studied. In the first regime, the fluid in the extracorporeal circuit was pumped by a peristaltic pump. In the second regime, the continuous pump was used in the extracorporeal circuit. The conditions were set to resemble those in vascular access during a hemodialysis session. Flow volume was set to 600 mL/min for vascular access and 200 mL/min for the extracorporeal circuit. Results. The main finding of this study was that the wall in the region of the arterial needle was stressed by backflow through the arterial needle. Since this was a variable, low-shear stress loading, it was one of the risk factors for the development of stenosis. Cyclic flow reversal was apparent in all of the included hemodialysis patients. The stereo PIV in vitro experiment revealed the oscillating character of wall shear stress (WSS) inside the model. High shear stress was documented upstream of the injection point of the arterial needle. An area of very low WSS was detected right behind the injection point during a pulse of the peristaltic pump. The minimal and maximal values of the WSS during a pulse of the peristaltic pump in the observed area were -0.7 Pa and 6 Pa, respectively. The distribution of wall shear stress with the continual pump used in the extracorporeal circuit was similar to the distribution during a pulse of the peristaltic one. However, the WSS values were continual; the WSS did not oscillate. WSS ranged between 4.8 Pa and 1.0 Pa.

Related Concept Videos

Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
183
Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
407
Hemodialysis III: Nursing Management01:25

Hemodialysis III: Nursing Management

The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this...
266
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis01:30

Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis

Patients with end-stage renal disease (ESRD) or those experiencing drug overdose often require extracorporeal methods to eliminate accumulated drugs and metabolites. Hemoperfusion, hemofiltration, and dialysis are the primary techniques to rapidly remove harmful substances without disrupting the patient's fluid and electrolyte balance. For those with compromised renal function, dosage adjustments of concurrent medications may be necessary during extracorporeal drug removal.Dialysis is a process...
27
Dialysis01:27

Dialysis

Renal failure occurs when the kidneys lose their ability to filter waste products from the blood effectively. It can be classified into two types: acute renal failure (ARF) and chronic renal failure (CRF).
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
615
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy01:26

Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy

Continuous Renal Replacement Therapy (CRRT) is an essential intervention for patients experiencing severe kidney dysfunction. This therapy offers a continuous mechanism for removing fluids and toxins from the bloodstream, leveraging the patient’s blood pressure to facilitate filtration through a specialized filter. This method contrasts with intermittent dialysis, providing a gentler and more consistent removal of waste products and excess fluid, which is particularly beneficial in...
13