Measuring Respiratory Function in Mice Using Unrestrained Whole-body Plethysmography
Published on: August 12, 2014
Wireless Wearable Ultrasound Sensor to Characterize Respiratory Behavior
Ang Chen1, Rachel Diane Rhoades2, Andrew Joshua Halton2
1School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ, USA. achen2021@outlook.com.
Abstract:
A wireless wearable sensor on a paper substrate was used to continuously monitor respiratory behavior that can extract and deliver clinically relevant respiratory parameters to a smartphone. Intended to be placed horizontally at the midpoint of the costal margin and the xiphoid process as determined through anatomical analysis and experimental test, the wearable sensor is compact at only 40 × 35 × 6 mm3 in size and 6.5 g weight including a 2.7 g lithium battery. The wearable sensor, consisting of an ultrasound emitter, an ultrasound receiver, wireless transmission system, and associated data acquisition, measures the linear change in circumference at the attachment location by recording and analyzing the changes in ultrasound pressure as the distance between the emitter and the receiver changes. Changes in ultrasound pressure corresponding to linear strain are converted to temporal lung volume data and are wirelessly transmitted to an associated custom-designed smartphone app. Processing the received data, the mobile app is able to display the temporal volume trace and the flow rate vs. volume loop graphs, which are standard plots used to analyze respiration. From the plots, the app is able to extract and display clinically relevant respiration parameters, including forced expiratory volume delivered in the first second of expiration (FEV1) and forced vital capacity (FVC). The sensor was evaluated with eight volunteers, showing a mean difference of the FEV1/FVC ratio as bounded by 0.00-4.25% when compared to the industry-standard spirometer results. By enabling continuous tracking of respiratory behavioral parameters, the wireless wearable sensor helps monitor the progression of chronic respiratory illnesses, including providing warnings to asthma patients and caregivers to pursue necessary medical assistance.
Related Concept Videos
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...