Thyrotoxicosis due to 1000-fold error in compounded liothyronine: A case elucidated by mass spectrometry

Wajid Khan1, Grace Van Der Gugten2, Daniel T Holmes2,3

  • 1Saba University School of Medicine, Saba, Caribbean, Netherlands.

Abstract

Related Concept Videos

Synthesis and Regulation of Thyroid Hormones01:20

Synthesis and Regulation of Thyroid Hormones

Low blood levels of the thyroid hormones — triiodothyronine (T3) and thyroxine (T4) — signal the hypothalamus to release the thyrotropin-releasing hormone (TRH). TRH then reaches the pituitary gland and stimulates the release of thyroid-stimulating hormone(TSH) into the bloodstream.
Upon reaching the thyroid gland, TSH stimulates the follicular cells' active uptake of iodide ions from the blood. The ions diffuse to the apical surface of the cells and are oxidized to iodine. The...
5.5K
Mass Spectrometry: Isotope Effect01:13

Mass Spectrometry: Isotope Effect

Most elements exist in nature as a mixture of isotopes. The isotopes differ in weight due to their respective number of neutrons. The molecular weight of a molecule is different depending on the specific isotope of its elements involved. As a result, the mass spectrum of the molecule exhibits peaks from the same fragment at multiple positions. The positions of these mass signals depend on the difference between the molecular mass. Furthermore, the intensity of these signals is dependent on the...
3.1K
Peptide Identification Using Tandem Mass Spectrometry01:33

Peptide Identification Using Tandem Mass Spectrometry

Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
7.2K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
683