Amplitude of movements with conical or spherical implants in anophthalmic socket
Carolina Pereira Bigheti1, Oscar Peitl2, Gabriel de Almeida Ferreira1
1Department of Ophthalmology, Medical School (FMB), São Paulo State University (Unesp), Botucatu, Brasil.
Purpose:
To evaluate the amplitude of movement in anophthalmic sockets reconstructed with conical or spherical orbital implants with and without an external ocular prosthesis (EOP), and whether the fornix depth could play a role.
Methods:
Prospective observational study involving unilateral anophthalmic sockets evaluated the amplitude of movement with conical (20 subjects) or spherical (16) non-porous orbital implants, with and without an EOP, having the contralateral eye as the control group. Standardized photographs were obtained in the four gaze directions and measurements were performed using the Image J software. The upper and lower fornix depths were measured using rulers.
Results:
Compared to the contralateral eye, the median movement amplitude without EOP was smaller with conical implants in supraduction (-0.88 mm, p=0.008), abduction (-2.26 mm, p<0.001) and adduction (-0.91 mm, p=0.008). Spherical implants had reduced movement only in abduction (-2.63 mm, p<0.001). Conical and spherical implants had similar amplitudes of movement in all versions, and were always smaller compared to the control. The median movement amplitude with the EOP was -3.05 mm (p=0.001) than without the EOP in abduction and -2.07 mm (p=0.020) in adduction, regardless of implant format. The fornix depth did not affect the orbital implants or EOP movement amplitude's median.
Conclusion:
Conical and spherical implants provide similar amplitude of movement and fornix depth did not have an influence on it. The amplitude of movement was significantly limited compared to the contralateral eye and was even more reduced if the EOP was in place with conical or spherical implant formats.
More Related Videos
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
12:25C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
Related Concept Videos
Accessory Structures of the Eye
Anatomical Movements
Here are some common anatomical movements:
Flexion and extension motions are in the sagittal (anterior–posterior) plane of motion. These movements take place at the shoulder, hip, elbow, knee, wrist,...
Eccentric Axial Loading in a Plane of Symmetry