Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
Published on: November 11, 2020
Experimental determination of modulation power of lung tissue for particle therapy
Jan Michael Burg1,2, Veronika Flatten1,2,3, Matthias Witt1,2,3
1University of Applied Sciences Giessen, Institute of Medical Physics and Radiation Protection, Germany.
Abstract:
In particle therapy of lung tumors, modulating effects on the particle beam may occur due to the microscopic structure of the lung tissue. These effects are caused by the heterogeneous nature of the lung tissue and cannot be completely taken into account during treatment planning, because these micro structures are too small to be fully resolved in the planning CT. In several publications, a new material parameter called modulation power (P) was introduced to characterize the effect. For various artificial lung surrogates, this parameter was measured and published by other groups and ranges up to approximately 1000μm. Studies investigating the influence of the modulation power on the dose distribution during irradiation are using this parameter in the rang of 100-800μm. More precise measurements forPon real lung tissue have not yet been published. In this work, the modulation power of real lung tissue was measured using porcine lungs in order to produce more reliable data ofPfor real lung tissue. For this purpose,ex-vivoporcine lungs were frozen in a ventilated state and measurements in a carbon ion-beam were performed. Due to the way the lungs were prepared and transferred to a solid state, the lung structures that modulate the beam could also be examined in detail using micro CT imaging. An optimization of the established methods of measuring the modulation power, which takes better account of the typical structures within lung tissue, was developed as well.