The key role of pulse wave transit time to predict blood pressure variation during anaesthesia induction
Guoqiang Hu1, Minjuan Chen1, Xiaodan Wang1
1Department of Anaesthesiology, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Taizhou, Zhejiang Province, China.
Objective:
To establish the relationship between pulse wave transit time (PWTT) before anaesthesia induction and blood pressure variability (BPV) during anaesthesia induction.
Methods:
This prospective observational cohort study enrolled consecutive patients that underwent elective surgery. Invasive arterial pressure, electrocardiography, pulse oximetry, heart rate and bispectral index were monitored. PWTT and BPV were measured with special software. Anaesthesia was induced with propofol, sufentanil and rocuronium.
Results:
A total of 54 patients were included in this study. There was no correlation between BPV and the dose of propofol, sufentanil and rocuronium during anaesthesia induction. Bivariate linear regression analysis demonstrated that PWTT (r = -0.54), age (r = 0.34) and systolic blood pressure (r = 0.31) significantly correlated with systolic blood pressure variability (SBPV). Only PWTT (r = -0.38) was significantly correlated with diastolic blood pressure variability (DBPV). Patients were stratified into high PWTT and low PWTT groups according to the mean PWTT value (96.8 ± 17.2 ms). Compared with the high PWTT group, the SBPV of the low PWTT group increased significantly by 3.4%. The DBPV of the low PWTT group increased significantly by 2.1% compared with the high PWTT group.
Conclusions:
PWTT, assessed before anaesthesia induction, may be an effective predictor of haemodynamic fluctuations during anaesthesia induction.
More Related Videos
Related Concept Videos
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Pulse
The pulse serves as a clinical...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: