Related Experiment Video
Updated: Oct 11, 2025

Simulation of Early Earth Hydrothermal Chimneys in a Thermal Gradient Environment
Published on: February 27, 2021
Thermal environment investigation of asymmetric radiation coupled with convection heating
Man Fan1,2,3, Jia Wang1, Lanlan Zhang1
1School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin, 300401 China.
Abstract:
The couple of radiation with convection heating owned advantages of less energy utilization, healthier and more comfortable indoor environment. However, local thermal discomfort was often induced by large vertical temperature difference and radiation asymmetry temperature. This work studied indoor thermal environment characteristics under different coupling ways of radiation and convection heating terminals through experiments and CFD simulation. The studied five scenarios were denoted as: (I) lateral air supply + adjacent side wall radiation, (II) lateral air supply + opposite side wall radiation, (III) lateral air supply + floor radiation, (IV) lateral air supply + adjacent side wall radiation + floor radiation, and (V) lateral air supply + opposite side wall radiation + floor radiation. The overall thermal comfort indices (including air diffusion performance index (ADPI), predicted mean vote (PMV), and predicted percent of dissatisfaction (PPD)) and local thermal comfort indices under different scenarios were investigated. For Scenarios I-III, the local dissatisfaction rates caused by vertical air temperature difference were 0.4%, 0.1%, and 0.2%, respectively, which belonged to "A" class according to the ISO-7730 Standard. While the vertical asymmetric radiation temperature of Scenario I/II was about 6.5 °C lower than that of Scenario III/IV/V. The ADPI for Scenarios III-V were about respectively 5.7%, 16.7%, and 21.0% higher than that of Scenarios I-II, indicating that a large radiation area and radiation angle coefficient could reduce the discomfort caused by radiant temperature asymmetry. The coupling mode improved local discomfort by decreasing vertical temperature difference and radiation asymmetry temperature wherefore improving the PMV from -1.6 to -1. The lateral air supply coupled with asymmetric radiation heating could potentially improve the thermal comfort of occupied area, while the comprehensive effect of thermal environmental improvement, energy-saving, and cost-effectiveness needes to be further investigated.
More Related Videos
Related Concept Videos
Mechanisms of Heat Transfer II
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Absorption of Radiation
Mechanisms of Heat Transfer I
Mechanisms of Heat Transfer
Conduction, accounting for approximately 3% of body heat loss at rest, is the process of exchanging heat between molecules of two materials in direct contact. This can result in both heat loss and gain. For instance, when the body is submerged in water, which conducts heat 20 times more effectively than air, it can either lose or gain significant...
Mechanism of heat transfer