Numerical investigation of impinging jet ventilation in ICUs: Is thermal stratification a problem?
Lei Wang1,2, Zhiqiang Wang3, Sirui Zhu3
1Institute of Refrigeration and Cryogenics/Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province, Zhejiang University, Hangzhou, China.
Abstract:
Intensive care units (ICUs) are the high incidence sites of hospital-acquired infections, where impinging jet ventilation (IJV) shows great potential. Thermal stratification of IJV and its effect on contaminants distribution were systematically investigated in this study. By changing the setting of heat source or the air change rates, the main driving force of supply airflow can be transformed between thermal buoyancy and inertial force, which can be quantitatively described by the dimensionless buoyant jet length scale (). For the investigated air change rates, namely 2 ACH to 12 ACH, varies between 0.20 and 2.80. The thermal buoyancy plays a dominant role in the movement of the horizontally exhaled airflow by the infector under low air change rate, where the temperature gradient is up to 2.45 °C/m. The flow center remains close to the breathing zone of the susceptible ahead, resulting into the highest exposure risk (6.6‰ for 10-µm particles). With higher heat flux of four PC monitors (from 0 W to 125.85 W for each monitor), the temperature gradient in ICU rises from 0.22 °C/m to 1.02 °C/m; however, the average normalized concentration of gaseous contaminants in the occupied zone is reduced from 0.81 to 0.37, because their thermal plumes are also able to carry containments around them to the ceiling-level readily. As the air change rate was increased to 8 ACH (), high momentum weakened the thermal stratification by reducing the temperature gradient to 0.37 °C/m and exhaled flow readily rose above the breathing zone; the intake fraction of susceptible patient located in front of the infector for 10-µm particles reduces to 0.8‰. This study proved the potential application of IJV in ICUs and provides theoretical guidance for its appropriate design.}.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Free Jet
Mechanical Ventilation I: Indication and Settings