Related Experiment Video
Updated: Oct 11, 2025

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope
Published on: April 7, 2014
Multimodal biomicroscopic system for the characterization of cells with high spatial phase sensitivity and sub-pixel
Shilpa Tayal1, Veena Singh1, Tejinder Kaur2
1Bio-photonics and Green Photonics Laboratory, Department of Physics, Indian Institute of Technology Delhi, New Delhi, India.
Abstract:
Multimodal analysis is highly advantageous for various biomedical applications including cancer and brain studies. Simultaneous measurement of quantitative phase with sub-pixel accuracy and fluorescence image is difficult to achieve in single measurement. Conventionally, off-axis interferograms are analyzed using the Fourier-transform method which limits the accuracy of the phase maps by pixel size, and usually the location of the carrier peak is in sub-pixel. We report a multimodal microscopic system consisting of high-resolution (HR) quantitative phase interferometer to retrieve sub-pixel accuracy in phase imaging and an oblique-illumination-based fluorescence imaging system which decouples the excited light from emitted signal light to avoid saturation of the camera, both integrated into a single unit. Here, highly resolved phase maps are obtained using a two-step process. First, using a speckle-free illumination which offers high spatial phase sensitivity. Second, using a hamming window for accurate estimation of original signal frequency information and HR discrete Fourier transform (DFT) which offers sub-pixel accuracy in phase measurements. HR-DFT has computational load of , where is the size of the interferogram and is the upsampling factor, making system computationally more robust and efficient compared to zero-padded FFT. The experiment is conducted on MG63 osteosarcoma and human mesenchymal stem cells (hMSCs) and their quantitative parameters are extracted with significantly improved accuracy. The average phase for MG63 cells and hMSCs, for nucleus is obtained to be 8.02 rad ± 0.80 rad and 4.29 rad ± 0.43 rad, respectively, and for cytoplasm is obtained to be 2.63 rad ± 0.96 rad and 1.73 rad ± 0.57 rad, respectively.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Three-Dimensional Microscopy in Microbiology