Related Experiment Video
Updated: Oct 11, 2025

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
A deep-learning reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography
Mengzhen Wang1, Jing Fan1, Xiaofeng Shi1
1Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, China.
Purpose:
To assess the image quality (IQ) of low tube voltage coronary CT angiography (CCTA) images reconstructed with deep learning image reconstruction (DLIR).
Methods:
According to body mass index (BMI), eighty patients who underwent 70kVp CCTA (Group A, N = 40, BMI ≤ 26 kg/m2) or 80kVp CCTA (Group B, N = 40, BMI > 26 kg/m2) were prospectively included. All images were reconstructed with four algorithms, including filtered back-projection (FBP), adaptive statistical iterative reconstruction-Veo at a level of 50% (ASiR-V50%), and DLIR at medium (DLIR-M) and high (DLIR-H) levels. Image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and edge rise distance (ERD) within aorta root and coronary arteries were calculated. The IQ was subjectively evaluated by using a 5-point scale.
Results:
Compared with FBP, ASiR-V50% and DLIR-M, DLIR-H led to the lowest noise (Group A: 24.7 ± 5.0HU; Group B, 21.6 ± 2.8 HU), highest SNR (Group A, 24.9 ± 5.0; Group B, 28.0 ± 5.8), CNR (Group A, 42.2 ± 15.2; Group B, 43.6 ± 10.5) and lowest ERD (Group A, 1.49 ± 0.30 mm; Group B, 1.50 ± 0.22 mm) with statistical significance (all P < 0.05). For the objective assessment, the percentages of 4 and 5 IQ scores were significantly higher for DLIR-H (Group A, 93.8%; Group B,90.0%) and DLIR-M (Group A, 85.6%; Group B,86.9 %) compared to ASiR-V50% (Group A, 58.8%; Group B, 58.8%) and FBP (Group A, 34.4%; Group B, 33.1%) algorithms (all P < 0.05).
Conclusion:
The application of DLIR significantly improves both objective and subjective IQ in low tube voltage CCTA compared with ASiR-V and FBP, which may promote a further radiation dose reduction in CCTA.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...